background image

4

DOUBLE INSULATION INSTRUCTIONS

This Wet/Dry Vacuum is double-insulated, eliminating the need for a separate grounding system. 

Use only identical replacement parts. Read the instructions for Servicing Double-Insulated Wet/Dry 

Vacuum before servicing. Use this Wet/Dry Vacuum as described in this manual.

Observe the following warnings that appear on the motor housing of your Wet/Dry Vac. 

When using as blower:

• Direct air discharge only at work area.

• Do not use Wet/Dry Vacuum as a sprayer.

• Do not direct air at bystanders.

• Keep children away when blowing.

• Wear safety goggles.

SAVE THESE INSTRUCTIONS

DOUBLE INSULATED - GROUNDING NOT REQUIRED - WHEN SERVICING USE ONLY 

IDENTICAL REPLACEMENT PARTS. 
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK - DO NOT EXPOSE TO 

RAIN. STORE INDOORS. 
WARNING: FOR YOUR OWN SAFETY, READ AND UNDERSTAND THE OPERATOR’S 

MANUAL.  DO NOT RUN UNATTENDED. DO NOT PICK UP HOT ASHES, COALS, 

TOXIC, FLAMMABLE OR OTHER HAZARDOUS MATERIALS. DO NOT USE AROUND 

EXPLOSIVE LIQUIDS OR VAPORS.

CAUTION: DO NOT VACUUM DRYWALL DUST, FIREPLACE SOOT, OR ASH. THIS 

TYPE OF DUST IS VERY FINE WHICH MAY NOT BE CAPTURED BY THE FILTER AND 

CAUSE DAMAGE TO MOTOR. 

WARNING:

                   

WITH A DOUBLE-INSULATED WET/DRY VACUUM, TWO SYSTEMS OF INSULATION 

ARE PROVIDED INSTEAD OF GROUNDING. NO GROUNDING MEANS IS PROVIDED 

ON A DOUBLE-INSULATED APPLIANCE, NOR SHOULD A MEANS FOR GROUNDING 

BE ADDED. SERVICING A DOUBLE INSULATED WET/DRY VACUUM REQUIRES 

EXTREME CARE AND KNOWLEDGE OF THE SYSTEM, AND SHOULD BE DONE 

ONLY BY QUALIFIED SERVICE PERSONNEL. REPLACEMENT PARTS FOR A 

DOUBLE-INSULATED WET/DRY VACUUM MUST BE IDENTICAL TO THE PARTS 

THEY REPLACE. YOUR DOUBLE-INSULATED WET/DRY VACUUM IS MARKED WITH 

THE WORDS ‘DOUBLE INSULATED’ AND THE SYMBOL         (SQUARE WITHIN A 

SQUARE) MAY ALSO BE MARKED ON THE APPLIANCE.

SERVICING OF DOUBLE-INSULATED WET/DRY VACUUM

Содержание VOM205P

Страница 1: ...before use Keep this manual for future reference 2 5 Gallon Model No VOM205P Operator s Manual Wet Dry Vacuum Distributed By Cleva North America Inc 601 Regent Park Court Greenville SC 29607 Replacement Filters Accessories available at Vacmaster com ...

Страница 2: ...ducing a high quality durable product This Vacmaster product carries a limited two 2 year warranty against defects in workmanship and materials from date of purchase under normal household use If product is to be used for commercial industrial or rental use a 90 day limited warranty will apply Please keep your receipt as proof of purchase This warranty gives you specific legal rights which may var...

Страница 3: ... rain Store indoors If vacuum is not working as it should has been dropped damaged left outdoors or dropped into water return it to a service center Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not use with damaged cord or plug Do not pull or carry by cord use cord as a handle close a door on cord or pull cord around sharp edges or corners Keep cord away from heated su...

Страница 4: ...AD AND UNDERSTAND THE OPERATOR S MANUAL DO NOT RUN UNATTENDED DO NOT PICK UP HOT ASHES COALS TOXIC FLAMMABLE OR OTHER HAZARDOUS MATERIALS DO NOT USE AROUND EXPLOSIVE LIQUIDS OR VAPORS CAUTION DO NOT VACUUM DRYWALL DUST FIREPLACE SOOT OR ASH THIS TYPE OF DUST IS VERY FINE WHICH MAY NOT BE CAPTURED BY THE FILTER AND CAUSE DAMAGE TO MOTOR WARNING WITH A DOUBLE INSULATED WET DRY VACUUM TWO SYSTEMS OF ...

Страница 5: ...ore than Not more than 0 6 18 16 16 14 6 10 18 16 14 12 10 12 16 16 14 12 12 16 14 12 Not recommended SYMBOLS The following signal words and meanings are intended to explain the levels of risk associated with this product SYMBOL SIGNAL MEANING DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a potentially hazardous sit...

Страница 6: ...his vacuum are 1 25 3 2 cm diameter G H I J F D C A B E Carton Contents List Key Description Q t y A Vacuum Assembly 1 B Wall Mount Bracket 1 C Hose 1 D Crevice Tool 1 E Utility Nozzle 1 F Reusable Cloth Filter 1 G Foam Wet Filter 1 H Handle 1 I 2 Screws Bag 1 J Operator s Manual 1 Accessory Storage Power Cord Hook Wall Mount Bracket Blower Port Handle Power Head Hose Organization On Off Switch Va...

Страница 7: ...le into place Fig 5 6 Your vacuum comes ready for dry vacuum cleaning If the reusable cloth filter is not installed refer to page 13 for installation instructions Fig 6 7 7 For wet vacuum cleaning remove the reusable cloth filter and install the supplied foam wet filter See page 13 for the foam wet filter installation instructions Fig 8 Tools Required for Assembly Philips Head Screwdriver Helpful ...

Страница 8: ...mpty the collection tank before mounting the vacuum on the wall 11 Make sure the bracket is level and mark the hole locations Make1 8 inch diameter pilot hole in each marked location Align the two screw holes so that they are over a stud and secure the wall mount bracket to the wall stud with the two screws provided Fig 13 12 Place the wet and dry vacuum cleaner into the wall mount bracket Fig 14 ...

Страница 9: ... on by flipping the switch to the I ON position and begin vacuuming Fig 8 8 Once you have completed vacuuming flip the switch to the O OFF position and unplug the power cord from the outlet O OFF I ON DO NOT USE THE REUSABLE CLOTH FILTER FOR LIQUID VACUUMING 8 8 7 2 3 4 5 6 WARNING BE SURE TO READ UNDERSTAND AND APPLY INFORMATION ENTITLED IMPORTANT SAFETY INSTRUCTIONS DO NOT VACUUM IN AREAS WITH F...

Страница 10: ... quantities of liquids do not immerse the nozzle completely in the liquid leave a gap at the tip of the nozzle opening to allow air inflow The machine is fitted with a float valve that stops the suction action when the collection tank reaches its maximum capacity You will notice an increase in motor speed When this happens turn off the machine disconnect from power supply and drain the liquid into...

Страница 11: ... onto the hose Fig 3 6 Verify that the power switch is in the O OFF position before plugging the power cord into the outlet Plug the power cord into the outlet Fig 4 5 7 Before turning on the vacuum firmly hold onto the loose end of the hose Turn the motor on by flipping the switch to the I ON position Fig 6 8 Once you have completed blowing flip the power switch to the O OFF position and unplug t...

Страница 12: ...ed are made of high quality materials designed to stop small dust particles The reusable cloth filter should be used for dry pick up only A dry reusable cloth filter is necessary to pick up dust If the reusable cloth filter is wet it will clog quickly and be very difficult to clean Handle the filter carefully when removing it for cleaning and replacing it Check the filters for tears or small holes...

Страница 13: ...ew filter is recommended 3 Use a mild soap and water solution to wash reusable cloth filter and rinse with clean water Fig 5 4 Allow the wet filter to air dry for 24 hours before installing onto the filter cage INSTALLING FOAM WET FILTER 1 Verify that the power cord is disconnected from the outlet Fig 1 2 Remove the power head and place in an upside down position Follow instructions to remove the ...

Страница 14: ...s full Empty the collection tank Switch in the wrong position Press the ON I button on the power head The dust comes out from the motor cover The reusable cloth filter is missing or damaged Attach or replace the reusable cloth filter Reduced efficiency and motor speed vibration There are blockages in the nozzle hose or the collection tank inlets Unplug and check nozzle hose and collection tank inl...

Страница 15: ...15 EXPLODED VIEW 1 2 3 4 5 6 8 7 10 9 11 12 13 ...

Страница 16: ...oat 1 4 551012116 Filter Cage 1 5 Collection Tank 1 6 551012104 Vacuum Port 1 7 551012107 Wall Mount Hook Assembly 1 8 551098111 Wall Mount Bracket Assembly 1 9 551012109 Crevice Tool 1 10 551004113 Utility Nozzle 1 11 551009111 Foam Wet Filter 1 12 551012110 Reusable Cloth Filter 1 13 551012108 Hose 1 ...

Отзывы: