background image

Distributed By

Cleva North America, Inc.

601 Regent Park Court

Greenville, SC  29607

Replacement Filters &

Accessories available at:

Vacmaster.com

FOR YOUR SAFETY

Read and understand this manual before use.

Keep this manual for future reference.

8 Gallon 

Model No.

 

VOC809PF

Operator’s Manual

Wet/Dry Vacuum

Содержание VOC809PF

Страница 1: ...nt Park Court Greenville SC 29607 Replacement Filters Accessories available at Vacmaster com FOR YOUR SAFETY Read and understand this manual before use Keep this manual for future reference 8 Gallon Model No VOC809PF Operator s Manual Wet Dry Vacuum ...

Страница 2: ...uality durable product This Vacmaster product carries a limited two 2 year warranty against defects in workmanship and materials from date of purchase under normal household use If product is to be used for commercial industrial or rental use a 90 day limited warranty will apply Please keep your receipt as proof of purchase This warranty gives you specific legal rights and you may have other right...

Страница 3: ...vacuum is not working as it should has been dropped damaged left outdoors or dropped into water return it to a service center Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not use with damaged cord or plug Do not pull or carry by cord use cord as a handle close a door on cord or pull cord around sharp edges or corners Keep cord away from heated surfaces Do not run the v...

Страница 4: ...O NOT RUN UNATTENDED DO NOT PICK UP HOT ASHES COALS TOXIC FLAMMABLE OR OTHER HAZARDOUS MATERIALS DO NOT USE AROUND EXPLOSIVE LIQUIDS OR VAPORS CAUTION DO NOT VACUUM DRYWALL DUST OR FIREPLACE SOOT OR ASH WITH STANDARD WET DRY FILTER THIS TYPE OF DUST IS VERY FINE WHICH MAY NOT BE CAPTURED BY THE FILTER AND CAUSE DAMAGE TO MOTOR WHEN VACUUMING FINE DUST USE A FINE DUST FILTER WARNING SERVICING OF DO...

Страница 5: ...OTICE Without Safety Alert Symbol Indicates a situation that may result in property damage EXTENSION CORDS When using an extension cord with your Wet Dry Vacuum refer to the following table to determine the required A W G wire size Before using the cleaner make sure the power cord and extension cord are in good working condition Make repairs or replacements before using the vacuum cleaner Only use...

Страница 6: ... List Key Description Qty NOTE The hose and accessories for this vacuum are 1 7 8 diameter 1 1 1 1 4 2 1 1 1 1 1 1 A B C D E F G H I J K L Vac Assembly Handle Hose Utility Nozzle Caster Foot Assembly Extension Wands Floor Nozzle Cartridge Filter Filter Retainer Foam Wet Filter 4 Screws Bag Operator s Manual Handle On Off Switch Vacuum Port Caster Foot Caster Power Head Hose Storage Latch Collectio...

Страница 7: ...nd tighten with supplied screws Verify that the casters are mounted correctly Do not over tighten screws Fig 5 6 Insert the handle into the slots located on the top of the power head and secure it with the screws provided Do not over tighten the screws Fig 6 7 Your vacuum comes ready for dry vacuum cleaning If the cartridge filter is not installed refer to page 13 for installation instructions Fig...

Страница 8: ...KE SURE PLUG IS DISCONNECTED BEFORE CHANGING THE FILTERS CAUTION DO NOT VACUUM DRYWALL DUST OR FIREPLACE SOOT OR ASH WITH STANDARD WET DRY FILTER THIS IS A VERY FINE DUST WHICH WILL NOT BE CAPTURED BY THE FILTER AND MAY CAUSE DAMAGE TO MOTOR WHEN VACUUMING FINE DUST USE A FINE DUST FILTER SOLD SEPARATELY DRY VACUUMING POLARIZED PLUG To reduce the risk of electrical shock this appliance has a polar...

Страница 9: ...Place the power head back on the collection tank and secure it in place using the latches Fig 6 OPERATING INSTRUCTIONS DRY VACUUMING 6 Insert the locking end of the hose into the vacuum port on the power head and turn to lock into place 7 Push the required attachment onto the free end of the hose or extension wand Fig 7 8 Verify that the switch is in the O OFF position before plugging the power co...

Страница 10: ...lean and free of dust and dirt Fig 1 2 Remove the cartridge filter then carefully install the foam wet filter over the filter cage and place the power head back on the collection tank For foam wet filter installation instructions see page 14 Fig 2 DO NOT USE THE CARTRIDGE FILTER FOR LIQUID VACUUMING OPERATING INSTRUCTIONS WET VACUUMING 3 Push the required attachment onto the free end of the hose o...

Страница 11: ...let Fig 4 5 7 Before turning on the vacuum firmly hold loose end of the hose Turn the motor on by flipping the switch to the I ON position Fig 6 8 Once you have completed blowing flip the power switch to the O OFF position and unplug the power cord from the outlet Fig 7 IMPORTANT When vacuuming large quantities of liquids do not immerse the nozzle completely in the liquid leave a gap at the tip of...

Страница 12: ...If the machine is used without the cartridge filter the motor will burn out and the warranty will be voided Always keep spare filters on hand NOTICE The filters included are made of high quality materials designed to stop small dust particles The cartridge filter should be used for dry pick up only A dry cartridge filter is necessary to pick up dust If the cartridge filter is wet it will clog quic...

Страница 13: ...ollection tank REMOVING AND CLEANING CARTRIDGE FILTER 1 Unlock and remove the filter retainer by turning retainer handle counter clockwise 2 With the removed power head in an upside down position carefully remove the cartridge filter from the filter cage Fig 6 3 Clean the cartridge filter by gently tapping or brushing dirt off Cleaning should not be done indoors in living areas For optimal perform...

Страница 14: ...FOAM WET FILTER TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION The wet dry vacuum will not operate No power supply Check the power supply cord breakers and fuses Faulty power cord Unplug and check the power cord If damaged have it repaired by a professional Collection tank is full Empty the collection tank Switch in the wrong position Press the ON I button on the power head The dust comes out fro...

Страница 15: ...15 EXPLODED VIEW ...

Страница 16: ...51005104 Filter Cage 1 5 Collection Tank 1 6 551011106 Vacuum Port Assembly 1 7 551002110 Drain Cap Assembly 1 8 551058106 Caster Foot Assembly 4 9 551264103 Extension Wand 2 10 551016112 Hose 1 11 VFF51 Foam Wet Filter 1 12 VCFS Cartridge Filter 1 13 551004104 Filter Retainer 1 14 551011110 Floor Nozzle 1 15 551011109 Utility Nozzle 1 ...

Отзывы: