background image

13

When reduction of air flow (≤20m/s) has occurred during operation, the air flow indicator next to the 
filter cleaning button located on top of the power head will admit a flashing red LED. If the suction 
performance diminishes, you can improve the suction power with the help of the filter cleaning 

system (Fig. 15).

1)  Position the end of the suction hose nozzle into the channel located within the filter cleaner 

button.

2)  Move the on/off switch to the “I” position.
3)  Turn the power regulator to the MAX position.
4)  Press the filter cleaning button down and hold it down for 3-4 seconds (Fig. 16).

5)  Repeat the process two more times.

5.  Wet & Dry Vacuum Operation

WARNING: ENSURE YOU READ, UNDERSTAND AND APPLY SECTION 

ENTITLED ‘SAFETY INFORMATION’. 

WARNING: DO NOT VACUUM IN AREAS WITH FLAMMABLE GASES, 

VAPOURS, OR EXPLOSIVE DUSTS IN THE AIR. FLAMMABLE GASES OR 

VAPOURS INCLUDE BUT ARE NOT LIMITED TO; LIGHTER FLUID, SOLVENT 

TYPE CLEANERS, OIL-BASE PAINTS, GASOLINE, ALCOHOL OR AEROSOL 

SPRAYS. EXPLOSIVE DUSTS INCLUDE BUT ARE NOT LIMITED TO; COAL, 

MAGNESIUM, GRAIN OR GUN POWDER. 

1)  Verify that the correct filter is installed and the container latches are secured. 

2)  Secure the locking end of the hose into the vacuum suction port.

3)  Push the desired accessories onto the hose nozzle. The air flow regulation allows you to change 

vacuum cleaner suction. For best cleaning results, fully close the air flow regulation (Fig. 17).

4)  Plug the power cord into a power outlet.
5)  Turn on the motor by assigning the switch to the “I” ON position.
6)  Once you have completed vacuuming, switch to the “O” OFF position and unplug the power 

cord from the power outlet.

For Dry Vacuuming: 

WARNING: BEFORE INSTALLING, REMOVING OR CLEANING THE VACUUM 

CLEANER FILTER, ENSURE THAT THE POWER CORD IS SWITCHED OFF 

AND UNPLUGGED. 

WARNING: ALWAYS USE A P2-RESPIRATOR WHEN VACUUMING 

HAZARDOUS DUSTS.

1)  To prepare your vacuum cleaner for dry vacuuming, install the cartridge filter over the filter 

cage. Carefully push filter until it sits flush forming a tight seal. Tighten the filter retainer lock 
clockwise to secure against the internal filter cage (Fig. 18).

2)  Install the dust bag and/or the disposable bag onto the suction port inlet. Refer to page 11 for 

installation instructions. 

IMPORTANT:

 Before picking up dust with occupational exposure limit values:

Check that all the filters are present and properly fitted.
For safety reasons, a visual warning indicator will activate if the air flow in the suction hose drops 
to below 20 m/s.

Содержание VMVDK1538SWC-06

Страница 1: ...VDK1538SWC 38L 1500W ORIGINAL INSTRUCTIONS...

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ...16 15 12 13 14 17 25 31 32 33 34 26 27 28 29 30 20 21 22 23 24 18 6 1 2 4 3 5 10 11 9 8 7 19...

Страница 6: ...LLY READ AND UNDERSTAND ALL INSTRUCTIONS SYMBOLS Caution Read instruction manual Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Vacuum cleaners...

Страница 7: ...cannot accept any liability for damage or accidents which arise due to a failure to follow these instructions and the safety information Never leave the appliance switched on unattended if you leave...

Страница 8: ...re changing or cleaning filter Unplug from power supply when not in use and before carrying out maintenance Do not cover the ventilation openings Do not vacuum with any ventilation openings blocked ke...

Страница 9: ...ng accident prevention regulations valid in the country of use observe recognized regulations for safety and proper use When dust removers are used the rate at which air is exchanged in the room must...

Страница 10: ...13 Filter Cleaning Button 25 Metal Extension Wand x3 2 Carry Handle 14 Air Flow Indicator 26 Foam Filter 3 Wing Knob 15 Hose Storage Rack 27 Cartridge Filter pre installed 4 Power Regulator 16 Accesso...

Страница 11: ...sposable bag when collecting debris the user runs the risk of voiding vacuum cleaner certification 1 To use a dust bag fully fit the dust bag flange onto the inlet stub Fig 6 2 To use a disposable bag...

Страница 12: ...Fig 14 MIN Reduced suction for applications which generate a low level of dust MAX Maximum suction performance for use in applications which generate a high level of dust 4 Filter Cleaning Operation I...

Страница 13: ...ured 2 Secure the locking end of the hose into the vacuum suction port 3 Push the desired accessories onto the hose nozzle The air flow regulation allows you to change vacuum cleaner suction For best...

Страница 14: ...ormance WARNING When using the disposable bag be careful not to vacuum heavy or sharp objects When removing the disposable bag use a P2 respirator and securley tie a knot in the disposable bag Do not...

Страница 15: ...ing hazardous dusts it is recommended to dispose of the cartridge filter within a sealed bag and dispose of in accordance with legal regulations IMPORTANT When manually cleaning the cartridge filter b...

Страница 16: ...uming Replace the foam filter with the cartridge filter Power tool take off socket does not work Power tool wattage is not compatible with the power tool take off socket Check the wattage is compatibl...

Страница 17: ...e disposed with other household wastes throughout the EU The machine must be delivered in rigid packaging to avoid damage during transportation The packaging and the machine itself are manufactured fr...

Страница 18: ......

Страница 19: ......

Страница 20: ...1 4 7 2 12 14 8 9 3 11 13 15 16 10 5 6 MAX MIN MAX MIN...

Страница 21: ...17 21 18 19 20...

Страница 22: ......

Страница 23: ...23...

Страница 24: ...VDK1538SWC Suzhou Cleva Electric Appliance Co Ltd No 8 Ting Rong Street Suzhou Industrial Park Suzhou Jiangsu Province China www cleva europe com Made in P R C...

Отзывы: