background image

 
 

 
 

 

 

 

 
 
 
 
 
 
LIQUID VACUUMING  
 

WARNING: 

BE SURE TO READ, UNDERSTAND, AND APPLY INFORMATION, ENTITLED ‘SAFETY 

INSTRUCTIONS & WARNINGS

’.  DO NOT VACUUM IN AREAS WITH FLAMMABLE GASES, VAPORS, 

OR EXPLOSIVE DUSTS IN THE AIR.  FLAMMABLE GASES OR VAPORS INCLUDE BUT ARE NOT 
LIMITED TO; LIGHTER FLUID, SOLVENT TYPE CLEANERS, OIL-BASE PAINTS, GASOLINE, ALCOHOL 
OR AEROSOL SPRAYS.  EXPLOSIVE DUSTS INCLUDE BUT ARE NOT LIMITED TO; COAL, 
MAGNESIUM, GRAIN OR GUN POWDER.  TO REDUCE THE RISK OF HEALTH HAZARDS FROM 
VAPORS OR DUST, DO NOT VACUUM TOXIC MATERIALS. 

 
WARNING

:  DO NOT PLUG IN POWER CORD TO POWER OUTLET, MAKE SURE PLUG IS 

DISCONNECTED BEFORE ASSEMBLING THE WET/DRY VAC 

 

1.  Verify that the power cord is disconnected from the outlet.  Verify that the container is clean and free of  
     dust and dirt.  (fig. 1) 
2.  Remove cartridge filter, then carefully install the foam sleeve filter over the filter cage and place the     
     power head back on the container.  (fig. 2)  See filter installing instructions on page 10. 
 

DO NOT USE THE CARTRIDGE FILTER FOR LIQUID VACUUMING. 

 

OPERATING INSTRUCTIONS 

– WET VACUUMING 

3.  Fit the desired nozzle to the vacuum hose.  (fig. 3)  
4.  

Verify that the switch is in the ‘O’ OFF position before plugging the power cord into the outlet.   (fig. 4)  

5.  

Turn the motor on by flipping the switch to the ‘I’ ON position.  (fig. 5) 

6.  After use, empty the container by unscrewing the drain cap.  Drain liquids into a suitable receptacle or drain. 

Remember to refit the drain cap to the container after draining container.  (fig. 6)

 

 

IMPORTANT!

  When vacuuming large quantities of liquids, do not immerse the nozzle completely in the 

liquid; leave a gap at the tip of the nozzle opening to allow air inflow.  The machine is fitted with a float valve 
that stops the suction action when the container reaches its maximum capacity.  You will notice an increase in 
motor speed.  When this happens, turn off the machine, disconnect from power supply, and drain the liquid 
into a suitable receptacle or drain.  To continue vacuuming, refit the container with the drain cap.  After wet 
vacuuming, turn the machine off and remove plug from power supply.  Empty the container, clean and dry the 
inside and outside before storage. 

 
REMEMBER!

 

The foam filter must be removed after wet vacuuming, and a cartridge filter must be installed 

before dry vacuuming again.  
 
 
 
 

 
 

LIQUID VACUUM OPERATION 

Содержание VJ809

Страница 1: ...Manual 12 Gallon Model No VJC1210PF FOR YOUR SAFETY Read and understand this manual before use Keep this manual for future reference www vacmaster com Cleva North America 44 Parkway Commons Greer SC 29650 Part No VJC1BZ 20 60 01 ...

Страница 2: ...0 day limited warranty will apply Warranty does not apply to defects due to direct or indirect abuse negligence misuse accidents repairs or alterations and lack of maintenance Please keep your receipt as proof of purchase This warranty gives you specific legal rights and you may have other rights which vary from state to state For product service call Customer Service at 866 384 8432 TABLE OF CONT...

Страница 3: ...h damaged cord plug or other parts If your Wet Dry Vac is not working as it should has missing parts has been dropped or damaged left outdoors or dropped into water return it to an independent service center Do not pull or carry by cord use cord as handle close a door on cord or pull cord around sharp edges or corners Do not run Wet Dry Vac over cord Do not handle plug or the Wet Dry Vac with wet ...

Страница 4: ... WARNING SERVICING OF DOUBLE INSULATED WET DRY VACUUMM WITH A DOUBLE INSULATED WET DRY VACUUM TWO SYSTEMS OF INSULATION ARE PROVIDED INSTEAD OF GROUNDING NO GROUNDING MEANS IS PROVIDED ON A DOUBLE INSULATED APPLIANCE NOR SHOULD A MEANS FOR GROUNDING BE ADDED SERVICING A DOUBLE INSULATED WET DRY VACUUM REQUIRES EXTREME CARE AND KNOWLEDGE OF THE SYSTEM AND SHOULD BE DONE ONLY BY QUALIFIED SERVICE PE...

Страница 5: ... Brush Squeegee I Cartridge Filter J Filter Retainer K Foam Sleeve Filter L 4 Screws Bag M Operator s Manual NOTE The hose and accessories for this vacuum are 2 5 diameter Length of Extension Cord 110V 120V 25 Feet 7 5 Meters 50 Feet 15 25 Meters 100 Feet 30 5 Meters 150 Feet 45 7 Meters Amps A W G Wire Size 0 6 18 16 16 14 7 10 18 16 14 12 11 12 16 16 14 12 13 16 14 12 Not recommended UNPACKING A...

Страница 6: ...sters are mounted correctly Do not over tighten screw fig 5 6 Your vacuum comes ready for dry vacuum cleaning If cartridge filter is not installed refer to page 10 for filter installation fig 6 7 7 For wet vacuum cleaning install the supplied foam filter fig 8 See page 10 for filter installation 8 Place the power head back on the container aligning the top section with the latches and snap into pl...

Страница 7: ...ST DO NOT VACUUM TOXIC MATERIALS 1 Verify that the power cord is disconnected from the outlet fig 1 2 In order to prepare your vacuum for dry vacuuming verify that the cartridge filter is securely mounted Make sure the filter is pushed in until it stops against the power head fig 2 Your Wet Dry Vac comes with the cartridge filter pre installed if not see page 10 for installation instructions 3 Pla...

Страница 8: ...NG 3 Fit the desired nozzle to the vacuum hose fig 3 4 Verify that the switch is in the O OFF position before plugging the power cord into the outlet fig 4 5 Turn the motor on by flipping the switch to the I ON position fig 5 6 After use empty the container by unscrewing the drain cap Drain liquids into a suitable receptacle or drain Remember to refit the drain cap to the container after draining ...

Страница 9: ... blowing port on the back side of the power head and lock into position fig 3 6 Fit the desired extension wand and or nozzle to the vacuum hose fig 4 7 Ensure the power switch is turned off and plug in the power supply fig 5 8 Before turning on the vac firmly hold loose end of the hose Turn the motor on by flipping the switch to the I ON position fig 6 1 Verify that the power cord is disconnected ...

Страница 10: ...r the filter cage with the flat end of the filter towards the vacuum power head Carefully push filter in until it stops against the power head fig 2 3 4 Place filter retainer on top of cartridge filter over the raise lip and tighten down by turning retainer Clockwise do not over tighten fig 4 5 Removing and Cleaning Cartridge Filter 1 Unlock and remove the filter retainer by tuning retainer handle ...

Страница 11: ...ill not operate 1 No power supply 1 Check power supply cord breakers fuses 2 Faulty power cord 2 Unplug and check the power cord If damaged have it repaired by a professional 3 Container full 3 Empty container Dust comes out from motor cover 1 The cartridge filter is missing or damaged 1 Attach or replace cartridge filter Reduced efficiency and motor speed vibration 1 There is a blockage in the no...

Страница 12: ...12 EXPLODED VIEW AND PARTS ...

Отзывы: