12
GB
The airflow can be continuously adjusted by turning the power regulator (Fig. 10).
MIN:
Reduced suction for applications which generate a low level of dust.
MAX:
Maximum suction performance for use in applications which generate a high level of dust.
4. Filter Cleaning Operation
IMPORTANT
:
Only perform the filter cleaning operation when the cartridge filter is installed.
If the suction performance diminishes, you can improve the suction power with the help of the filter
cleaning system.
1) Position the end of the suction hose nozzle into the channel located within the filter cleaner
button.
2) Move the on/off switch to the “I” position.
3) Turn the power regulator to the
MAX
position.
4) Press the filter cleaning button down and hold it down for 3-4 seconds (Fig. 11).
5) Repeat the process two more times.
5. Wet & Dry Vacuum Operation
WARNING!
ENSURE YOU READ, UNDERSTAND AND APPLY SECTION
ENTITLED ‘SAFETY INFORMATION’.
1) Verify that the correct filter is installed and the container latches are secured.
2) Secure the locking end of the hose into the vacuum suction port.
3) Push the desired accessories onto the hose nozzle. The air flow regulation allows you to
change vacuum cleaner suction. For best cleaning results, fully close the air flow regulation
(Fig. 12).
4) Plug the power cord into a power outlet.
5) Turn on the motor by assigning the switch to the “I” ON position.
6) Once you have completed vacuuming, switch to the “O” OFF position and unplug the power
cord from the power outlet.
For Dry Vacuuming:
WARNING:
BEFORE INSTALLING, REMOVING OR CLEANING THE VACUUM
CLEANER FILTER, ENSURE THAT THE POWER CORD IS UNPLUGGED AND
SWITCHED OFF.
1) To prepare your vacuum cleaner for dry vacuuming, install the cartridge filter over the filter
cage. Carefully push filter until it sits flush forming a tight seal. Tighten the filter retainer lock
clockwise to secure against the internal filter cage (Fig. 13).
3) Switch the vacuum cleaner to position II, as described in Switching ON/OFF. The moment you
switch on the power tool, the vacuum cleaner will also switch on. Once the electrical appliance
has been switched off, the vacuum cleaner switches off following a time lapse
(around 5 seconds) to allow the suction tube to be emptied.
3. Power Regulator
2. Power Tool Take-Off Operation (Fig. 9)
WARNING:
Always check the maximum wattage compatibility of the power tool take
off socket against the desired power tool before connecting to prevent overloading.
1) Connect the power cable of your power tool to the power take-off socket.
2) If applicable, connect the vacuum suction hose to the dust extractor connector on your tool with
the supplied adaptor.
Содержание VDK1430SFC
Страница 1: ...VDK1430SFC 30L 1400W Original Instructions...
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 5: ...1 2 3 9 10 13 14 15 16 22 17 23 20 21 26 19 25 18 24 11 12 4 5 6 7 8...
Страница 18: ......
Страница 19: ......
Страница 20: ...1 1 5 1 2 4 13 12 11 14 3 7 9 6 MAX MIN MAX MIN 15 16 8 10...
Страница 21: ......
Страница 22: ...22 GB...
Страница 23: ...23 GB...