GATE DELAY DURING CLOSING
In order to avoid the colliding of gate's during the closing the
time of delay should de introduced r.Ch, which is adjustable
from 0 to 2 minutes. In such a case the closing time of
gate1 is delayed in comparison to the gate2.
BACKLASH TIME
To avoid that the gate star ts the opening phase before the
electrical locks is unhooked, it is possible to introduce a time
of inversion adjustable from 0 to 3 seconds. In this way
during the opening phase, the gate inver ts the motion through
the set time permitting the unhooking of the electrical lock.
PRE-FLASHING TIME
This menu permits the introduction of a pre-flashing that
occurs before any movement of the gate either in opening or
in closing phase: the time of pre-flashing can be adjusted
from 0 to 2 minutes.
END OF STROKE SLOWING DOWN
Such a menu allows enabling the door slowing down at their
end of stroke by means of two speeds which can be set up
according to your needs.
vEL1
corresponds to 25% of power.
vEL2
corresponds to 50% of power.
MOTOR 1 POWER
Such a menu enables the sensitivity adjusting of the motor 1
current sensor from 1 to 10.
START SLOWING DOWN
Such a menu enables the motor slowing down star t as for
the opening and closing phase.
MOTOR 2 POWER
Such a menu enables the sensitivity adjusting of the motor 1
current sensor from 2 to 10.
LOCK TIME
Before the opening phase star ts, the gearcase has to energi-
ze the electrical lock in order to release it and enable the
gate movement. The time t.SEr determines the duration of
excitation, and is adjustable from 0 to 3 seconds. In case
there is no motor lock, set up on
no
.