25
PHOTO 2 INPUT
The photocell 2 is active in closing: if it is dimmed during the
closing it stops the gate and inver ts the motion. The option CFCh
activates the photocell even when the gate is still: closed gate
means that no impulse has been given, either it is in pause or it has
received a STOP command. In this case through all the time of the
darkening of the photocell the control unit does not receive any com-
mand of activation at any opening / closing cycle.
CFCh
the input PHOTO 2 is available: the photocell is active in
closing and also when the gate is still
no
the input PHOTO 2 is not available
Ch
the input PHOTO 2 is available: the photocell is active
only during the closing
END OF PROGRAMMING
This menu allows to finish the programming (both default and
personalized) saving the modified data into memor y.
no
fur ther corrections to carr y out: do not quit the
programming
Si
end of programming
THE INSERTED DATA HAVE BEEN MEMORIZED: THE CONTROL
UNIT IS READY TO BE USED.
COUNTER VIEWING
Such a menu allows viewing the number of opera-
tion cycles which such automatism carries out and
it also enables the final user to set up a limit
value in order to show him when the actuators
ser vice is required.
tot
.
Total number of completed cycles (the
display views in thousands, press DOWN
to view units).
SErv
number of cycles before the next request
for ser vice.
Such a function is disabled by default, by pressing
UP the display will view -01.0, which shows a
1000-cycle countdown after which PD9 will show
the final user that a ser vice is required. Such a
number has been rounded off to hundreds and it
can be set up on 1000-step; set up the desired
value, and then press MENU to confirm.
The request for a ser vice will be signalled by means of double blinks
during the whole operation cycle.
WARNING
: only a qualified staff shall carr y out all ser vice operations.
Once the ser vice has been carried out, the relevant ser vice menu
SErv
shall be set up again.
PD9 will continue signalling the request for a ser vice until such para-
meter is not set up.