NOTIFICATIONS
The battery charge status is displayed by means of LEDs located on the front of the box.
Checking must be performed with the gate resting.
The yellow LED
flashes to indicate the batteries are charging; if the LED is fixed, it means the charge current is very low, or there is very
little sun or the batteries are already fully charged.
The green LED
flashes to indicate the batteries are charged. The rate of flashing increases as the charge level decreases.
The red LED
flashes when the batteries have lost their charge. The red LED remains on if the charge level is dangerously low.
m
PLEASE NOTE: Never allow the battery to discharge to the point where the red LED remains on, since this risks
irreparable damage to the battery.
RECHARGING THE BATTERIES FROM THE MAINS SUPPLY
In the case of prolonged absence of charging from the sun, the batteries may be recharged using the mains power supply (accessory code
172802). This operation may also be recommended prior to installation in order to be certain of maximum battery life.
Disconnect both connectors and optionally remove the fixing bolt and remove the module from the bracket.
Move the accumulator unit close to a power socket in a protected environment.
m
PLEASE NOTE: The mains charger is not built to operate outdoors.
Connect the power supply to the grey connector; insert the plug into a power socket: the yellow LED starts to flash.
When the LED remains on, charging is complete and the unit may be disconnected.
m
PLEASE NOTE: both before and after charging, when the accumulator unit is inactive, do not connect anything to the
grey terminal; this way, the batteries remain disconnected and there is no unnecessary power consumption.
REPLACING THE BATTERIES
m
PLEASE NOTE: the batteries should only
be replaced by qualified technical staff
Replacement of the accumulators becomes
necessary when battery life is significantly reduced
due to ageing.
In any case, it is recommended they should be
replaced after five years of use.
m
PLEASE NOTE:
always replace both
batteries with new batteries of the same model
(12 V – 18 Ah). NEVER mix new and old batteries
at the same time.
m
PLEASE NOTE:
accumulators contain lead
and other pollutants; certain electronic
components may contain pollutants: do not
dispose of them with normal waste, but use the
methods prescribed in local regulations.
To replace the batteries, proceed as follows:
1.
Disconnect both connectors
2.
Open the casing by unscrewing the 4 screws
under the handles
3.
Disconnect the batteries by unscrewing the
screws on the terminals
4.
Remove the old batteries and insert new ones
in the same positions
5.
Reconnect the cables, ensuring the polarities are
correct, and tighten the screws properly
6.
Close the casing and reconnect the grey and
black connectors
Содержание ECO-LOGIC
Страница 2: ......
Страница 8: ...ITALIANO 6 ...
Страница 14: ...ENGLISH 12 ...
Страница 20: ...FRANÇAIS 18 ...
Страница 26: ...ESPAÑOL 24 ...
Страница 32: ...PORTUGUÊS 30 ...
Страница 38: ...DEUTSCH 36 ...
Страница 44: ...NEDERLANDS 42 ...
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 48: ......