IMPORTANT REMARKS
For any installation problem please contact our
Customer Service at the 39-0172.812411
operating Monday to Friday from 8:30 to 12:30
and from 14:00 to 18:00.
V2 has the right to modify the product
without previous notice; it also declines any
responsibility to damage or injury to people or
things caused by improper use or wrong
installation.
m
Please read this instruction manual very
carefully before installing and programming
your control unit.
• This instruction manual is only for qualified
technicians, who specialize in installations and
automations.
• The contents of this instruction manual do not
concern the end user.
• Every programming and/or every maintenance
service should be done only by qualified
technicians.
AUTOMATION MUST BE IMPLEMENTED IN
COMPLIANCE WITH THE EUROPEAN
REGULATIONS IN FORCE:
EN 60204-1
(Machinery safety. electrical equipment
of machines, part 1: general rules)
EN 12445
(Safe use of automated locking
devices, test methods)
EN 12453
(Safe use of automated locking
devices, requirements)
• The installer must provide for a device
(es. magnetotermical switch) ensuring the
omnipolar sectioning of the equipment from the
power supply. The standards require a
separation of the contacts of at least 3 mm in
each pole (EN 60335-1).
• After making connections on the terminal
board, use one hose clamp to fix dangerous
voltage wires near the terminal board and
another hose clamp to fix safety low voltage
wires used for accessories connection; this way,
in case of accidental detachment of a
conducting wire, dangerous voltage parts will
not come into contact with safety low voltage
ones.
• The plastic case has an IP55 insulation; to
connect flexible or rigid pipes, use pipefittings
having the same insulation level.
• Installation requires mechanical and electrical
skills, therefore it shall be carried out by
qualified personnel only, who can issue the
Compliance Certificate concerning the whole
installation (EEC Machine Directive
2006/42/CEE, Annex IIA).
• The automated vehicular gates shall comply
with the following rules: EN 13241-1,
EN 12453, EN 12445 as well as any local rule in
force.
• Also the automation upstream electric system
shall comply with the laws and rules in force
and be carried out workmanlike.
• The door thrust force adjustment shall be
measured by means of a proper tool and
adjusted according to the max. limits, which
EN 12453 allows.
• Connect the earthing lead of the motors to the
electricity grid earth system.
• Observe all necessary precautions (e.g. anti-static
bracelet) for handling parts sensitive to
electrostatic discharges.
DECLARATION OF CONFORMITY
V2 S.p.A. hereby declare that CITY7 products
conform to the essential requirements established
in the following directives:
-
2004/108/CEE
(EMC Directive in accordance
with standards EN 61000-6-2, EN 61000-6-3 +
EN 50336)
-
2006/95/CEE
(Low Voltage Directive in
accordance with standards EN 60335-1 +
EN 60335-2-103)
-
99/05/CEE
(Radio Directive in accordance with
standard EN 301 489-3)