PARAMETER
VALUE
DESCRIPTION
DEFAULT
MEMO
SPAP
Pedestrian Start during the partial opening phase
This menu allows fixing the control unit conduct in case it receives a
Pedestrian Start command during the partial opening phase.
m
WARNING:
a Start command in any phase of partial opening will
cause the total opening; the Start Pedestrian command is always ignored
during a total opening.
PAUS
PAUS
The gate stops and goes to pause
ChiU
The gate immediately starts closing
no
The gate goes on with the opening phase (command is ignored)
Ch.AU
Automatic closing
no
no
Function deactivated
0.5” - 20.0’
The gate closes after the setup time
Ch.tr
Closing after transit
This function allows having a fast closing as soon as transit through the
gate is completed, therefore, a time shorter than
Ch.AU
is generally used
no
no
Function deactivated. The gate closes after the time set for the
function
Ch.AU
0.5” - 20.0’
The gate closes after the setup time
PA.tr
Pause after transit
Per rendere minimo il tempo in cui il cancello rimane aperto, è possibile
fare in modo che il cancello si fermi non appena viene rilevato il passaggio
davanti alle fotocellule. Se abilitato il funzionamento automatico, come
tempo di pausa viene caricato il valore
Ch.tr
no
no
Function deactivated
Si
Function activated
LUCi
Courtesy lights
This menu allows setting the automatic operating of the courtesy lights
during the opening cycle of the gate.
CiCL
t .LUC
Timed operation (from 0 to 20 min)
no
Function disabled
CiCL
On for the entire cycle duration
AUS
Auxiliary channel
This menu allows setting the operating of the relay of the lighting of the
courtesy lights by means of a remote control stored on the channel 4 of
the receiver.
Mon
t iM
Timed operation (from 0 to 20 s)
biSt
Bistable operation
Mon
Monostable operation