V2 Calypso 400-120V Скачать руководство пользователя страница 11

ENGLISH

11

PROGRAMMING THE OPERATIONAL LOGIC

It is possible for the control unit to use several different operational logic states, by simply moving the dip-switches located on the card.
The functions associated with each individual dip-switch are listed below.

DIP

FUNCTION

SETTING

DESCRIPTION

1

Pre-flashing

ON

Disabled

The blinker is switched on when the motors are started

OFF

Enabled

The blinker is switched on for 2 seconds before the motors are started

2

Automatic
closure

ON

Enabled

The gate is closed automatically after the period of time set by the PAUSE
trimmer

OFF

Disabled

On completion of the opening step, the gate remains open. It is necessary to
instruct closure with another START command

3

Start opening

ON

Not accepted

Any START command issued during opening is ignored

OFF

Accepted

Any START command issued during opening is accepted

4

Operational logic

ON

Inversion

Start during opening causes closure. 
Start during closure causes opening.

OFF

Step

Commands subsequent to starting cause, in order: 
open 

rt

stop 

rt

close 

rt

stop...

5

Slow down

ON

Enabled

At the end of each opening and closing step, the motors slow down in order to
avoid noisy closure and bouncing.

OFF

Disabled

6

Start off

ON

Disabled

At the start of each opening and closing step, the motors are started at
maximum power 

OFF

Enabled

7

Anti-slip

ON

Disabled

The time used for opening or closure will always be the value set by the WORK
trimmer, even if the previous operation has been interrupted before the expiry
of such time.

OFF

Enabled

When an opening (or closing) operation is interrupted before expiry of the set
time (for example due to the intervention of one of the safety devices or due to
a start command), the duration of the subsequent closing (or opening)
operation will not be that set by the WORK trimmer, but will be equal to the
time effectively elapsed, plus a short supplemental time in order to compensate
for the inertia of the gate.

8

Photocell

ON

Always active

Intervention of the photocell during opening or closing causes the gate to stop.
When the photocell restores, the gate re-opens completely.

OFF

NOT active during
opening:

Intervention of the photocell during opening is ignored. Intervention of the
photocell during closing causes the gate to re-open completely.

9

Photocell test

ON

Enabled

The control unit performs a photocell operational test before starting each
opening or closing operation. If the photocells are not operating correctly, the
gate does not begin to move and the light flashes for approx. 8 seconds.

PLEASE NOTE:  connect the photocell TX correctly

OFF

Disabled

10

Safety edge 
type

ON

Conductive rubber
edge

Select this option if using conductive rubber edges with nominal resistance of
8K2.

OFF

Standard or optical
edge

Select this option if using standard edges with switch normally closed or optical
edges.

11

Safety edge

ON

Always active

Intervention of the edge during opening or closing causes inversion of the
direction of movement in order to free the body that caused the edge to
intervene. The gate will be stopped after approx. 3 seconds.

OFF

NOT active during
opening:

Intervention of the edge during opening is ignored. Intervention of the edge
during closing causes the gate to be re-opened completely.

12

Safety edge test

ON

Enabled

The control unit performs an operational test on the edges before starting each
opening or closing operation. If the edges are not operating correctly, the gate
does not begin to move and the light flashes for approx. 8 seconds. 

DO NOT enable testing if conductive rubber edges are used or standard
edges are used without a suitable control unit for controlling function.

OFF

Disabled

Содержание Calypso 400-120V

Страница 1: ...NOTICES D EMPLOI ET D INSTALLATION NICHT UMKEHRBARER ELEKTROMECHANISCHER ANTRIEB F R FL GELTORE BEDIENUNGSANLEITUNGEN UND INSTALLATION OPERADOR ELECTROMECANICO IRREVERSIBLE PARA CANCELAS BATIENTES INS...

Страница 2: ...urrent A 1 1 2 2 Full load current A 1 4 1 4 2 8 2 8 Maximum Power W 300 300 300 300 Capacitor F 8 8 25 25 Max travel mm 400 500 400 500 Operating speed m s 0 016 0 016 0 018 0 018 Maximum thrust N 26...

Страница 3: ...PS The new series of actuadors CALYPSO has been devised to serve gates up to 500 Kg with leaf up to 3 meters wide look at the table technical data Before proceeding with the installation please make s...

Страница 4: ...40 150 140 1000 60 170 150 990 80 190 150 980 100 200 150 980 120 210 140 980 140 250 120 1010 100 20 130 170 970 40 150 180 960 60 170 180 960 80 190 170 970 100 210 140 990 110 20 130 190 950 40 15...

Страница 5: ...the actuators Position CALYPSO on the brackets and fix the pins no 1 and no 2 with seeger see the picture Open and close the swings repeatedly manually to verify the absence of frictions between gate...

Страница 6: ...CY RELEASE In case of a blackout the gate can be operated directly from the motor Insert the key supplied in the lock perform 1 2 of a turn To restore the automation simply rotate the key in closed po...

Страница 7: ...E POUR PORTAILS BATTANTS CUADRO DE MANIOBRA ANAL GICO PARA CANCELAS A BATIENTE QUADRO DE COMANDO ANAL GICO PARA PORT ES DE BATENTE I GB F E P IL n 252 1 EDIZ 12 11 2007 V2 S p A Corso Principi di Piem...

Страница 8: ...rol unit POWER motor power WORK motor operating time 5 120 seconds m PLEASE NOTE it is recommended that operating times be set with the slow down function disabled DIP 5 OFF PAUSE pause time before au...

Страница 9: ...two settings 1 Photocell always active Intervention of the photocell during opening or closing causes the gate to stop When the photocell restores the gate re opens completely 2 Photocell NOT active d...

Страница 10: ...ox half way of the gate leaf connected to motor 1 Subsequent pedestrian start commands will function according to step logic During a pedestrian cycle the start command results in the complete opening...

Страница 11: ...uent closing or opening operation will not be that set by the WORK trimmer but will be equal to the time effectively elapsed plus a short supplemental time in order to compensate for the inertia of th...