background image

E

N

G

L

IS

H

9

PRELIMINARY OPERATIONS

The new series of actuadors BLITZ, has been devised to serve gates up to 800 Kg with leaf up to 3 meters wide (look at the table technical
data). Before proceeding with the installation, please make sure that your gate opens and closes freely, and that:

• Pintles and pivots shall be in good order and properly lubricated
• Nothing shall block the movement
• No friction with earth and between the doors shall exist (mechanical expansion from 7 to 8 mm min.)
• Your gate has to be equipped with central stop (1) and possibly side limits (2)

INSTALLATION MEASURES

To carry out a proper installation of the operator parts as well as to ensure the best automation performance, the measurement levels
shown in the following table shall be complied with. Change the gate structure to adapt it to one of the cases in the table, if necessary.

γγ

B [mm]

A [mm]

C [mm]

90°

20 ÷ 40

140

650

50 ÷ 80

140

650

90 ÷ 140

150

650

150 ÷ 160

160

650

170 ÷ 180

180

650

180 ÷ 220

180

650

220 ÷ 250

180

600

250 ÷ 320

200

600

100°

20 ÷ 60

170

650

70 ÷ 110

180

650

110 ÷ 150

190

650

150 ÷ 200

200

650

110°

20 ÷ 50

180

650

50 ÷ 100

200

650

110 ÷ 130

210

650

Содержание BLITZ-24V

Страница 1: ...SIBLE DE BRAZO ARTICULADO PARA CANCELAS BATIENTES MOTORREDUTOR ELECTROMEC NICO IRREVERS VEL COM BRA O ARTICULADO PARA PORT ES DE BATENTE ELEKTROMECHANISCHER IRREVERSIBLER STELLANTRIEB MIT GELENKARM F...

Страница 2: ......

Страница 3: ...e automation upstream electric system shall comply with the laws and rules in force and be carried out workmanlike The door thrust force adjustment shall be measured by means of a proper tool and adju...

Страница 4: ...rking temperature C 30 60 30 60 30 60 Thermal protection C 140 140 140 Working cycle 80 20 20 Motor weight Kg 14 6 14 6 14 6 INSTALLATION LAYOUT 1 BLITZ actuator cable 4 x 1 mm2 cable 1 5 x 2 mm2 Blit...

Страница 5: ...pansion from 7 to 8 mm min Your gate has to be equipped with central stop 1 and possibly side limits 2 INSTALLATION MEASURES To carry out a proper installation of the operator parts as well as to ensu...

Страница 6: ...t and fasten the screw Release the ratiomotor see paragraph EMERGENCY LOCK RELEASE Mark the front bracket fastening points on the door according to the previous established levels Separate the front b...

Страница 7: ...204 1 BLITZ 24V ADJUSTMENT OF STOP ENDS Opening stop end release the actuator and put the door into its opening position Adjust the cam LOWER for the RIGHT motor and UPPER for the LEFT motor until the...

Страница 8: ...directly from the motor Insert the key supplied in the lock perform 1 2 of a turn Open the door and turn the release lever to position 2 Turn again the release lever to position 1 close the door turn...

Страница 9: ......

Отзывы: