ENGLISH
- 51 -
PARAMETER
VALUE
DESCRIPTION
DEFAULT
MEMO
SPiA
Setting low voltage exit lights
This menu makes to possible to set the flashing exit function
FLSh
FLSh
Flasher operation (fixed frequency)
no
Not used
W.L.
Indicator light operation: Indicates the status of the gate in real-time.
The type of blinking indicates the four possible conditions:
- GATE STOPPED: Light off
- GATE IN PAUSE: the light is on, fixed
- GATE OPENING: the light blinks slowly (2 Hz)
- GATE CLOSING: the light blinks quickly (4 Hz)
LP.PA
Blinker during pause time
no
no
Function deactivated
Si
The blinker will be on during the pause time too (gate open with
automatic closure active)
Strt
Activation inputs (START and START P.)
This menu allows selecting input operation modes (see chapter 4.3)
StAn
StAn
Standard mode
no
Start inputs from terminal board are disabled.
Radio inputs operate in standard mode
StAn
AP.Ch
Open/Close command
PrES
Manned operation
oroL
Timer mode
StoP
Stop Input
no
no
The input STOP is not available (ignored by the control unit)
ProS
The input STOP stops the gate: pressing the command START the gate
continues the motion
invE
The command STOP stops the gate: at the next START the gate starts
moving in the opposite direction
Fot1
Photocell 1 input
This menu allows enabling the input for type 1 photocells, that is to say,
photocells active both during the opening and closing phase
no
no
Input disabled (ignored by the control unit)
AP.Ch
Input enabled
Fot2
Photocell 2 input
This menu allows enabling the input for type 2 photocells, that is to say,
photocells non active during the opening phase
CFCh
CFCh
Input enabled even at standstill gate too: the opening movement does not
start if photocell is interrupte
Ch
Input enabled for the closing phase only
Warning: if you select this option, you must disable photocell test
no
Input disabled (ignored by the control unit)
Ft.tE
Test of the photocells
In order to achieve a safer operation for the user, the unit performs a
photocells operational test, before a normal working cycle.
If no operational faults are found, the gate starts moving.
Otherwise, it will stand still and the flashing light will stay onfor 5 sec.
The whole test cycle lasts less than one second.
no
no
Function deactivated
Si
Function activated