10.3 - LOADING THE DEFAULT
PARAMETERS
If necessary, it is possible to restore all parameters to their
standard or default values (see the final summary table).
m
PLEASE NOTE: This procedure results in the loss of all
customised parameters.
1.
Press and hold the
OK
key until the display shows
-dEF
2.
Release the
OK
key: the display shows
ESC
(only press the
OK
key if it is desired to exit this menu)
3.
Press the
i
key: the display shows
dEF
4.
Press the
OK
key: the display shows
no
5.
Press the
i
key: the display shows
YES
6.
Press the
OK
key: all parameters are overwritten with their
default values (see Chapter 12), the control units exits
programming mode and the display shows the control panel.
dEF.
ESC
-dEF
Si
no
SEnS
SEnS
ESC
-SEn
10.2 - AUTOMATIC SENSITIVITY
ADJUSTMENT
1.
Press and hold the
OK
button until the display shows
-SEn
2.
Release the
OK
button: the display shows
ESC
(press
OK
only if you want to exit this menu)
3.
Press the
i
key: the display shows
SEnS
4.
Press the
OK
button to start the procedure: the message
SEnS
flashes on the display and the gate performs a full
closing cycle until reaching the end of stroke (complete
opening phase and complete closing phase).
5.
When the procedure is finished, the display shows the control
panel
m
ATTENTION: if the control unit receives a START
command during the automatic learning procedure, the
procedure is aborted and the control unit stores the partial
data determined.