15
Faults
Sometimes certain faults detected can be easily
resolved. Before calling the Technical Assistance
Service, bear in mind the following advice:
Fault
Possible cause
Solution
The general electrical
system is
malfunctioning.
Defective fuse.
The automatic safety
switch has tripped or a
fuse has blown.
Check the fuse in the main fuse box
and change it if it is damaged.
Check the main control panel to see
if the automatic safety switch has
tripped or a fuse has blown.
The automatic ON
function does not
work.
There may be food or
cleaning products stuck
between the ignition
sparker and the burner.
The burner is wet.
The burner covers are not
correctly positioned.
The appliance is either not
earthed, not connected
properly or the earth
connection is fault.
The space between the ignition
sparker and the burner must be
clean.
Dry the burner covers carefully.
Check that the covers are correctly
positioned.
Contact an electrical engineer.
The burner flame is
not uniform.
The burner components
are not correctly
positioned.
The grooves on diffuser
are dirty.
Ensure the components are
correctly positioned
Clean the grooves on the diffuser.
The flow of gas does
not appear normal or
no gas comes out.
The gas mains are turned
off.
If the gas is supplied from
a gas bottle, check that
this is not empty.
Turn on all stop cocks.
Change the gas bottle.
The kitchen smells of
gas.
A gas tap has been left
on.
There may be a leak from
the coupling to the gas
bottle.
Turn off the gas taps.
Check that the coupling is sound.
The safety valve on
the burner is not
working.
The control knob was not
held down for long
enough.
The grooves on the
diffuser are dirty.
Once the burner is lit, hold the
control knob down a few seconds
longer.
Clean the grooves on the diffuser.