Accessory parts
Type
Height C
Article no.
C
292
DFPQ5, DFPQ6, DFPQ9, DFPQ12
410-790 mm
H4.2614
DFPQ5, DFPQ6, DFPQ9, DFPQ12
791-1150 mm
H4.2615
Electrical connections
Electrical connections must be carried out by trained electricians in accordance with the guidelines and standards for low-
voltage installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug
and socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles
switching are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors
ensure safe and fault-free operation. After installation, live parts and cables with basic insulation must not be accessible.
Check old installations.
The appliance is designed for use up to a max. altitude of 2000 m above sea level.
See the identification plate for information on the necessary mains voltage, type of current and fuse protection.
Warning: Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards.
Do not cut off the plug.
Installation instructions
J61001.113-1
Range hood DFPQ5/DFPQ6/DFPQ9/DFPQ12
09.10.13
Built-in hood
Operating modes: extracted air/recirculation air
2