4 Care and maintenance
4.3
Standard activated charcoal filter
The standard activated charcoal filter needs replacing after an operating period of 3 to 6
months. Standard activated charcoal filters cannot be washed or regenerated.
Removing/Installing
▸ Pull the deflector plate completely
out and switch the appliance off.
▸ Remove the metal grease filters.
▸ Remove the activated charcoal filter
1
. Observe the guide/locking device
on the outside of the activated char-
coal filter.
▸ Dispose of spent activated charcoal
filter
1
at a suitable recycling point
2
.
▸ Insert new activated charcoal filter
3
of the same type, ensuring that the
locking device is positioned cor-
rectly.
2
1
3
4.4
Replacing the LED light bulbs
Disconnect the appliance from the mains and disengage the fuse or automatic cir-
cuit breaker.
Removing/Installing
▸ Remove both grease filters.
–
The light cover can be accessed
from the back.
▸ Replace the light bulb with a new
light bulb of the same type (see des-
ignation on the light bulb housing or
on the identification plate).
▸ Insert the grease filters and engage
the fuse or automatic circuit breaker.