background image

4 Care and maintenance

4.3 

Long-life-Plus activated charcoal filter

The long-life-Plus activated charcoal filter should be cleaned and regenerated every 3 to
6 months with normal use and whenever the saturation indicator alarm is triggered. De-
pending on intensity of use, do not exceed 5–8 regeneration cycles. If properly cared for,
the service life of the long-life-Plus activated charcoal filter is up to three years.

Switch off the power supply to the appliance.

Removing

3

200°C

1h

2

1

▸ Remove the metal grease filters.
▸ Using the handle 

, remove the activated charcoal filter unit 

 down and out of the

guide rail.

Cleaning and regenerating

▸ Heat the activated charcoal filter unit 

 in the oven 

.

▸ Select top/bottom heat or hot air at 200 °C and regenerate on the wire shelf for 60

minutes.

▸ Allow to cool down.

After heat regeneration in the oven, allow the activated charcoal filter to cool down
before putting it back in the range hood. Risk of burns!

▸ Reassemble in the reverse order.
▸ Reset saturation indicator alarm (see page 18).

Dispose of the spent long-life-Plus activated charcoal filter at a suitable recycling
point.

17

Содержание AiroClearCabinet V4000

Страница 1: ...Operating instructions AiroClearCabinet V4000 Range hood...

Страница 2: ...spond to the technical standard of the appliance at the time these operating instructions went to press The right to make technical modifications for the purpose of the further development of the appl...

Страница 3: ...liance 9 3 1 Using for the first time 9 3 2 Switching the appliance on off 10 3 3 Selecting power level 10 3 4 Illumination 11 3 5 After running time 11 3 6 Saturation indicators 12 3 7 OptiLink 12 3...

Страница 4: ...e This appliance can be used by children aged 8 and above and by persons with reduced physical sensory or mental capabilities or lack of experi ence and or knowledge provided they are supervised or ha...

Страница 5: ...be observed from the in stallation instructions of this appliance WARNING Before replacing the light bulb ensure the ap pliance is switched off and disconnected from the mains power supply to avoid po...

Страница 6: ...rboarding wall pa pering or painting work is to be carried out prior to installing the appliance Efficient repairs can only be guaranteed if it is possible to de install the complete appliance at any...

Страница 7: ...means When cleaning the appliance make sure no water gets inside it Use a mod erately damp cloth only Do not spray the inside or outside of the appliance with water Do not use a steam cleaner If water...

Страница 8: ...ith activated charcoal filter A fan extracts cooking fumes and smells from above the cooking surface The air is passed through the metal grease filter and activated charcoal filter grease particles an...

Страница 9: ...al for the activated charcoal filter is 180 operating hours This default setting can be adjusted to suit your cooking habits Setting up the appliance for use in the recirculation mode To activate the...

Страница 10: ...n indicator is deactivated The setting selected is accepted after 5 seconds and the LEDs stop flashing after 10 seconds The appliance is now configured for the extraction mode and the saturation indic...

Страница 11: ...eached The colour temperature selected will be automatically accepted The illumination can be used independently of the extractor fan 3 5 After running time The purpose of the after running time funct...

Страница 12: ...see page 9 3 7 OptiLink With this function the user no longer needs to control the range hood manually OptiLink monitors the power levels set for the cooking zones and automatically sets the optimum...

Страница 13: ...sing the corresponding button Five seconds after the last entry the setting that was selected is saved How the range hood behaves when OptiLink is activated When OptiLink is turned on The range hood i...

Страница 14: ...shooting connection error No connection can be established between the range hood and the hob Ensure that the hob is in connecting mode Turn off the OptiLink function on the hob Hold the button on th...

Страница 15: ...ated Switching the appliance on off Touch the button The appliance switches on at power level 1 Touch the button again The appliance switches off Switching the illumination on off Touch the button The...

Страница 16: ...be cleaned at least every two months with normal use more frequently with intensive use and whenever the saturation indicator alarm is triggered If properly cared for the grease filters should provide...

Страница 17: ...pliance Removing 3 200 C 1h 2 1 Remove the metal grease filters Using the handle remove the activated charcoal filter unit down and out of the guide rail Cleaning and regenerating Heat the activated c...

Страница 18: ...died please call Customer Services Before calling Customer Services Please note down the serial number for SN see iden tification plate under Technical data and what led to the fault Malfunction Possi...

Страница 19: ...Long life Plus activated charcoal filter Remote control 7 Technical data Electrical connection Accessing the identification plate Remove the metal grease filters The identification plate is located o...

Страница 20: ...um speed intensive or boost excluded Qmax m3 h 427 427 Air flow at intensive or boost setting Qboost m3 h 598 598 Airborne acoustical A weighted Sound Power Emissions at minimum speed SPEmin dBA 49 49...

Страница 21: ...pliance from the mains With a fixed appliance this is to be carried out by a qualified electrician Then cut the mains cable off flush with the appliance 8 3 Disposal The crossed out wheeled bin symbol...

Страница 22: ...rol 15 Initial set up 6 M Model designation 2 Model number 2 O Operating and display elements 9 Operating the appliance 9 OptiLink 12 P Product fiche 21 Q Queries 23 R Recirculation mode 8 Remote cont...

Страница 23: ...ee period You will require the serial number SN and appliance designation to register your appliance You will find them on the identification plate of your appliance My appliance information SN ______...

Страница 24: ...vel 3 and intensive level flashing Activate after running time Saturation indicator for metal grease filter flashing Saturation indicator for activated charcoal filter flashing V ZUG Ltd Industriestra...

Отзывы: