Installation instructions

Washing machine «Front loader»
One-family household

J267.370-0

25.6.09  ITH

3

For Service and Spare Part Information please contact:
Manfred Schulz, Technical Manager
V-ZUG AUSTRALIA PTY LTD, c/o C.W. Stirling
6th floor 90 William Street, Melbourne, VIC 3000
[email protected]
Tel/ Fax +61 3 9723 5790, Mob +61 400 088336

* This only applies if no plumbing fittings are to be installed behind the appliance.

Tools: Combination spanner 

H

 (supplied) and spirit level 

J

Rear adjuster feet:

A

Loosen counter nut 

K

.

A

Align the appliance vertically – by turning the feet by hand.

A

Tighten counter nut.

Front adjuster feet:

A

Slide appliance onto installation plate.

A

Loosen counter nut 

K

.

A

Align the appliance vertically – by turning the feet by hand.

Appliance must not wobble.

A

Tighten counter nut.

Water inlet

Only cold water G¾", possible pressure range 0.1–1.0 MPa (1–10 bar).

The appliance must not be connected to a mixer tap or a continuous flow boiler!

A pressure reduction valve is integrated in the sanitary installation. The water pressure is set at an optimal 
level of <0.2 MPa (2 bar) in order to avoid water hammer.

A

The tap seal seat must be clean and flat.

A

Connect Dual-Check-Valve to the water tap and tighten with pipe pliers.

A

Connect the hose to the Dual-Check-Valve and tighten with pipe pliers.

A

Install the hose without bending or twisting it.

A

Check the seal.

A

Where accessible, also fix hose to rear wall with adhesive base (see figure «Water outlet»).

Positioning in a niche

A

Centre the installation plate in the niche.

* Depth of niche including appliance door: min. 630 mm

* Depth of niche without appliance door:

min. 600 mm

4. Levelling

To ensure fault-free operation, the appliance must be perfectly vertical with all 4 feet standing firmly on the floor and must not
wobble. The counter nuts must be securely tightened so that the set height of the appliance is unaffected by any movement of
the appliance.

5. Plumbing in

Always observe the local water supply authority’s regulations.

Any old water supply and drain hoses must always be replaced with new hoses.

25

G

F

Appliance door

Installation plate

Niche

F

G

min. 600

Niche widt

h

Cut-out for lateral
connections, to the
left or right side
min. 100 × 100 mm

Niche height
min. 860 mm!

H

J

K