4. Positioning the installation plate

General tips

Use the installation plate supplied to install the appliance. It fixes the appliance in position, and is for use with both
free-standing appliances and appliances positioned in a niche.

The use of an unsuitable installation plate or a soft, sound-insulating underlay can affect the proper functioning of the appli-
ance.

In case of underfloor heating, do not drill holes in the floor! Adhere installation plate into place!

1

E

45

D

Fold out spacers 

D

 in order to keep dis-

tance to the back wall.

1

2

2

ø6

Variant 1:

 Without underfloor heating:

Fasten installation plate to the floor with
3 screws.

Dampen mounting slots 

E

 with water to

make the appliance easier to push in.

Variant 2: 

With underfloor heating:

Holes must not be drilled in the floor if
the room has 

underfloor heating

. The

installation plate must be adhered to the
floor.

Dampen mounting slots 

E

 with water to

make the appliance easier to push in.

Free-standing position

If a tumble dryer and a washing machine are positioned side by side, keep a distance of min. 5 mm between the in-
stallation plates and to the walls at the side and min. 45 mm to the back wall. The installation plates for the washing
machine and tumble dryer are the same.

1

45

5

595

510

5

555

D

Fold out spacers 

D

 in order to keep dis-

tance to the back wall.

Dimensions 45 and 555 only apply if no
plumbing fittings are to be installed be-
hind the appliance.

Содержание 11025

Страница 1: ...ut being shaken the appliance may be tilted a maximum of 90 to the right viewed from the front Applicable only to model 11025 In the event that the appliance is tilted during transportation or install...

Страница 2: ...and pull to the left The appliance door opens Variant 2 Right hand hinge door Insert tool D into blue emergency door release and pull to the right The appliance door opens 2 Removing the transportati...

Страница 3: ...2 3 1 213 80 72 160 45 595 33 625 850 125 500 577 500 50 42 15 84 5 725 550 458 104 Open door 1059 Left hand opening Right hand opening Open door 1059 Cold water connection 1 inlet hose with Aquastop...

Страница 4: ...1 Without underfloor heating Fasten installation plate to the floor with 3 screws Dampen mounting slots E with water to make the appliance easier to push in Variant 2 With underfloor heating Holes mus...

Страница 5: ...on offset for installation plate D 50 mm Variant 2 Niche front B and appliance door E are flush Niche depth A 645 mm Installation offset for installation plate D 83 mm 5 Levelling To ensure fault free...

Страница 6: ...nd flat Install hose without kinking or twisting it Check for leaks Water outlet When installing the drain hose protect it against damage and kinks Installing the drain hose Work steps Hose clamp Drai...

Страница 7: ...evices Effective earthing and separately installed neutral and earth conductors ensure safe and fault free operation After installation live parts and cables with basic insulation must not be accessib...

Страница 8: ...e display appears Creating unbal anced load please wait After 2 minutes in the display appears Check stability 9 Realign adjuster feet if necessary The appliance must stand level with all 4 feet firml...

Отзывы: