6. Door Station Configurations
1. About room code(address):
Room Code(also called room address) is a code assigned to each monitor, to identify different
monitors; each monitor have a unique room code in one buidling.The room Code is stored in
each Monitor’s inner EEPROM memory, and does not lose even the monitor is power off.
2. About Debug State:
The Debug State is your starting point for using all the applications on DMR18S.
When Door Station is in
standby, press '#' key
Press "2#" key to exit out the debug state.
input '9008', then input the
Admin Code.(66666666 by
default)
Debug State menu is launched
[ 9 0 0 8 ]
Please Input Password
1
2
3
6
5
4
7
8
9
#
0
*
RF CARD
> > D e b u g S t a t e < <
1 - # To o l s
0 - # R e d i a l
2 - # E x i t s
3. About Debug Tools:
During working at Debug State,press "1#" to enter tools page,Debug Tools overviews is
shown as below:
1 . I n s t a l l e r S e t u p
2 . S e t u p
3 . C a r d M a n a g e
4 . O n l i n e M o n i t o r s
5 . O n l i n e D e v i c e s
6 . Vo l t a g e M e a s u r e
Pres NO.
to select
*Back
Tools
> > D e b u g S t a t e < <
0 - # R e d i a l
2 - # E x i t s
1 - # To o l s
-7-