V-Tec DMR18S Скачать руководство пользователя страница 10

Basic Tools Detail:

Item

 Description

Factory 

set

ID Code

If only one door station is installed in this building, set 

to 0;

If multi door stations are installed, primary door station 

must be set to 0, and other slave door stations must 

be set from 1 to 3. Note that max. 4 door stations are 

available in one building 

[0]

Single

Unlock Timing

To set the time that how long the door keeps open 

when door is released. Range from 01 to 99 seconds.

[01]

1 seconds

Unlock Output 

To set the unlock mode to match the corresponding 

lock.Range from 0 to 1.

0:Power-on-to-Unlock Mode(Normally Open Mode)

1:Power-off-to-Unlock Mode(Normally Closed Mode)

0

Monitor Timing

To show the monitor time,Range from 6s to 600s

600s

Doorplate Mode

To set the calling mode.If set to 0,it's the auto 

mode,that means the calling will be activated directly 

after inputting 2 digits code.If set to 1,it's the manual 

mode,that means you should press "#" button to 

activate the calling after inputting the code.

[0]

Auto mode

Waiting Timing

To show the calling wait time,Range from 6s to 600s

40s

 Talking Timing  

To show the limitation time of talking,Range from 6s to 

600s

90s

Installer Code ...

To change door station administrator code 

[66666666]

Default ...

Note this operation is irreversible. Once restore is 

activated, all parameters will return to factory default 

setting except the information of access card.

Table 2(Installer Setup):

-9-

Содержание DMR18S

Страница 1: ...tion Please read this manual carefully before using the product you purchase and keep it well for future use We reserve the right to modify the specification in this manual at any time without notice...

Страница 2: ...B EB N O LK LK 12V L2 1 2 3 1 2 3 12V 12VDC power output LK GND Power ground LK COM Common contact of the Relay NO Normally open contact of the Relay refer to DT technical guide for Lock connection de...

Страница 3: ...ach the rainy cover to the wall Attach screws to fix the metal box Attach the unit to the rainy cover correctlly The last view for all mounting The view for rainy cover after mounted Adjust the camera...

Страница 4: ...ach the unit to the rainy cover correctlly Attach the baffle to protect the unit from droping The last view for all mounting The view for rainy cover after mounted Adjust the camera angle and attach t...

Страница 5: ...4A A B C D Impedance switch Impedance switch NOTE Here we take DT47M the monitor for example 100 240VAC BUS IM BUS DS PC6 AC Code 2 Code 1 Code 3 Code 28 Code 30 Code 29 Code 31 1 2 3 6 5 4 7 8 9 0 RF...

Страница 6: ...and the COM connect to the positive Jumper set to 1 2 position for Power off to Unlock safety type Normally closed mode set to 2 3 position for Power on to Unlock type Normally open mode If different...

Страница 7: ...nic lock is over 12 Vdc additional power supply for the lock is needed The power supply for the lock must be less than 48Vdc 1 5A The Jumper must be removed when using external power supply The defaul...

Страница 8: ...Station is in standby press key Press 2 key to exit out the debug state input 9008 then input the Admin Code 66666666 by default Debug State menu is launched 9 0 0 8 Please Input Password 1 2 3 6 5 4...

Страница 9: ...3 4 Unlock Code 1111 5 Work Mode 0 6 Clock 7 Setup Code 8 About 9 Default 3 Card Manage 1 Add Card 2 Delete By Card 3 Delete By M code 4 Cards Information 5 Format 4 Online Monitors To search the onl...

Страница 10: ...to Unlock Mode Normally Closed Mode 0 Monitor Timing To show the monitor time Range from 6s to 600s 600s Doorplate Mode To set the calling mode If set to 0 it s the auto mode that means the calling wi...

Страница 11: ...set to 1 date format is MM DD YY Time format if set to 0 time format is 24 hour standard If set to 1 time format is12 hour standard Setup Code To change the Program Code 88888888 About 1 Hardware ver...

Страница 12: ...the informations about cards Format To format informations about cards Table 4 Card Manage 4 How to use code unlock function Please refer to the following operations Please Input Password 1 2 3 6 5 4...

Страница 13: ...to update 6 User Card Management This section explains how to configure the key fob function on DMR18S The key fob is used to open the lock Total 320 key fobs can be registered with one door station...

Страница 14: ...ion is in Delete Card Mode 2 Delete by room number delete all the registered User Cards related to that room number 1 A d d C a r d Back Save Please Input Room Code 1 A d d C a r d Back Save Show the...

Страница 15: ...save format operation is activated all card information will be cleared 4 C a r d s I n f o r m a t i o n Back Save Card Count 320 5 F o r m a t Back Save Please Input Password 7 Specification Power...

Страница 16: ...DT ENG DMR18S V1 2015S0520...

Отзывы: