Basic Tools Detail:
Item
Description
Factory
set
ID Code
If only one door station is installed in this building, set
to 0;
If multi door stations are installed, primary door station
must be set to 0, and other slave door stations must
be set from 1 to 3. Note that max. 4 door stations are
available in one building
[0]
Single
Unlock Timing
To set the time that how long the door keeps open
when door is released. Range from 01 to 99 seconds.
[01]
1 seconds
Unlock Output
To set the unlock mode to match the corresponding
lock.Range from 0 to 1.
0:Power-on-to-Unlock Mode(Normally Open Mode)
1:Power-off-to-Unlock Mode(Normally Closed Mode)
0
Monitor Timing
To show the monitor time,Range from 6s to 600s
600s
Doorplate Mode
To set the calling mode.If set to 0,it's the auto
mode,that means the calling will be activated directly
after inputting 2 digits code.If set to 1,it's the manual
mode,that means you should press "#" button to
activate the calling after inputting the code.
[0]
Auto mode
Waiting Timing
To show the calling wait time,Range from 6s to 600s
40s
Talking Timing
To show the limitation time of talking,Range from 6s to
600s
90s
Installer Code ...
To change door station administrator code
[66666666]
Default ...
Note this operation is irreversible. Once restore is
activated, all parameters will return to factory default
setting except the information of access card.
Table 2(Installer Setup):