Door Station

Please read this manual carefully before using the product you purchase, and keep it well for future 

use.We reserve the right to modify the specification in this manual at any time without notice.

1

2

3

6

5

4

7

8

9

#

0

*

RF CARD

Содержание DMR18S

Страница 1: ...tion Please read this manual carefully before using the product you purchase and keep it well for future use We reserve the right to modify the specification in this manual at any time without notice...

Страница 2: ...B EB N O LK LK 12V L2 1 2 3 1 2 3 12V 12VDC power output LK GND Power ground LK COM Common contact of the Relay NO Normally open contact of the Relay refer to DT technical guide for Lock connection de...

Страница 3: ...ach the rainy cover to the wall Attach screws to fix the metal box Attach the unit to the rainy cover correctlly The last view for all mounting The view for rainy cover after mounted Adjust the camera...

Страница 4: ...ach the unit to the rainy cover correctlly Attach the baffle to protect the unit from droping The last view for all mounting The view for rainy cover after mounted Adjust the camera angle and attach t...

Страница 5: ...4A A B C D Impedance switch Impedance switch NOTE Here we take DT47M the monitor for example 100 240VAC BUS IM BUS DS PC6 AC Code 2 Code 1 Code 3 Code 28 Code 30 Code 29 Code 31 1 2 3 6 5 4 7 8 9 0 RF...

Страница 6: ...and the COM connect to the positive Jumper set to 1 2 position for Power off to Unlock safety type Normally closed mode set to 2 3 position for Power on to Unlock type Normally open mode If different...

Страница 7: ...nic lock is over 12 Vdc additional power supply for the lock is needed The power supply for the lock must be less than 48Vdc 1 5A The Jumper must be removed when using external power supply The defaul...

Страница 8: ...Station is in standby press key Press 2 key to exit out the debug state input 9008 then input the Admin Code 66666666 by default Debug State menu is launched 9 0 0 8 Please Input Password 1 2 3 6 5 4...

Страница 9: ...3 4 Unlock Code 1111 5 Work Mode 0 6 Clock 7 Setup Code 8 About 9 Default 3 Card Manage 1 Add Card 2 Delete By Card 3 Delete By M code 4 Cards Information 5 Format 4 Online Monitors To search the onl...

Страница 10: ...to Unlock Mode Normally Closed Mode 0 Monitor Timing To show the monitor time Range from 6s to 600s 600s Doorplate Mode To set the calling mode If set to 0 it s the auto mode that means the calling wi...

Страница 11: ...set to 1 date format is MM DD YY Time format if set to 0 time format is 24 hour standard If set to 1 time format is12 hour standard Setup Code To change the Program Code 88888888 About 1 Hardware ver...

Страница 12: ...the informations about cards Format To format informations about cards Table 4 Card Manage 4 How to use code unlock function Please refer to the following operations Please Input Password 1 2 3 6 5 4...

Страница 13: ...to update 6 User Card Management This section explains how to configure the key fob function on DMR18S The key fob is used to open the lock Total 320 key fobs can be registered with one door station...

Страница 14: ...ion is in Delete Card Mode 2 Delete by room number delete all the registered User Cards related to that room number 1 A d d C a r d Back Save Please Input Room Code 1 A d d C a r d Back Save Show the...

Страница 15: ...save format operation is activated all card information will be cleared 4 C a r d s I n f o r m a t i o n Back Save Card Count 320 5 F o r m a t Back Save Please Input Password 7 Specification Power...