background image

1.Registration

Go to

Solarman Smart App and

register.

Click "Register" and create your 

account here.

2.Create a Plant

Click "Add Now" to create your plant.

Please fill in plant basic info and 

other info here.

USAGE METHODS AND NOTICES FOR RESET BUTTON

Usage methods and key-press descriptions for Reset button

NOTICES FOR RESET BUTTON

USER MANUAL FOR SOLARMAN SMART APP

Notice:

Do not remove waterproof plug.

Key-press

Status Descrip

Ɵ

on

Light Status

Short press 1s SMARTLINK rapid networking status.

NET light

Ň

ashes fast for 100ms.

Long press 5s

Reboo

Ɵ

ng the 

WIFI Module

.

All lights are ex

Ɵ

nguished immediately.

Long press 10s

ZĞƐĞƫŶŐƚŚĞ

WIFI Module

.

1.All lights are ex

Ɵ

nguished a

Ō

er 4s.

2.READY light

Ň

ashes fast for 100ms.

Содержание VT-6607005

Страница 1: ...ual in multiple languages WEEE Number 80133970 5kW ON GRID INVERTER INSTRUCTION MANUAL MODEL VT 6607005 SKU 11832 IN CASE OF ANY QUERY ISSUE WITH THE PRODUCT PLEASE REACH OUT TO US AT SUPPORT VTACEXPO...

Страница 2: ...ectrical Connection 4 1 PV Connection 4 2 Grid Connection 4 3 Communication Connection 4 4 Zero injection Smart Meter Optional 5 Operation 5 1 Control Panel 5 2 Menu Structure 5 3 Setting 5 3 1 Startu...

Страница 3: ...anual must only be performed by qualified personnel Single Phase Ongrid Inverter VT 6607005 Please Keep This Manual All The Time Available In Case Of Emergency The typical on grid PV system connection...

Страница 4: ...minal discharge current 20KA second grade lightning protection protection voltage 3 2KV The wiring distance between the inverter and the distribution box should be at least 5 meters 2 Safety Symbols 2...

Страница 5: ...instructions and cautions during installation operation and maintenance 2 2 Explanations of Symbols Danger of electric shock The inverter contains fatal DC and AC power All work on the inverter must b...

Страница 6: ...tructions Qty Items No Qty Items 3 Installation 3 1 Pre installation 3 1 1 Unpacking Package List Unpacking On receiving the inverter please check to make sure the packing and all components are not m...

Страница 7: ...1 2 Product Overview No 1 2 3 4 5 6 DC Switch DC Connectors For PV Strings DC Connectors For PV Strings AC Connector Monitor Module Port Zero Injection Port Optional Items 360 mm 358 mm 142 mm 1 2 3 4...

Страница 8: ...rface far from flammable or corrosion materials where is suitable for inverter s weight and dimensions The ambient temperature should be within 25 60 between 13 F and 140 F The installation of inverte...

Страница 9: ...Leave the enough space around inverter easy for accessing to the inverter connection points and maintenance Step 1 Step 2 Installation 07 300mm 100mm 100mm 500mm 43 25mm 43 25mm 207mm 18 5mm 312mm Se...

Страница 10: ...The open circuit voltage and short circuit current of PV string should not exceed the reasonable range of the inverters The isolation resistance between PV string and ground must exceed 10 k The polar...

Страница 11: ...Step 1 Note PV cable suggestion Cross section 4mm Step 2 Note Please use PV connector crimper to pinch the point of the arrow Step 3 MC STOP MC MC STOP MC Note You ll hear click sound when the connec...

Страница 12: ...strings into one channel Channel A and B connected with PV strings separately PV Array 1 PV PV PV PV PV Array 2 PV Inverter PV Array 1 PV PV PV PV PV Array 2 PV Inverter Note PV string suggestion Cor...

Страница 13: ...age should not exceed the reasonable range of the inverters The phase line from AC distribution box are correctly connected Use the AC plugs in the accessory The surge protector should be equipped bet...

Страница 14: ...ctrical Connection 12 Step 4 1 Connect AC terminals and waterproof head tighten the cap make sure they clip closely together 2 Connect AC connector to AC terminal of the inverter 3 Afeer making sure t...

Страница 15: ...could transmit the data to the cloud server and display the data on the PC tablet and smart phone WIFI Ethernet GPRS RS485 communication is applicable to the inverter Please refer to Communication Co...

Страница 16: ...ent which is used for on grid inverters Its main function is to measure the forward and reverse power on the grid connected side and transmit data to the inverter through RS485 communication to ensure...

Страница 17: ...ad power not exceed Smart Mater s limitation Grid Load RS485 WiFi Ethernet GPRS Router Cloud Server Weather Sta on Smart Meter PV Array Energy Meter PV Inverter PV Array PV Array Note Please refer to...

Страница 18: ...Button 5 6 8 7 FAULT LED Indicator POWER LED Indicator ENT Touch Button GRID LED Indicator Sign Color Explanation POWER Green ON OFF ON OFF ON OFF Green Red FAULT The inverter is stand by The inverter...

Страница 19: ...ge Volt Range Del Err Record 10min OVR Coefficient Del Arr Record Q Var Mode Inverter Info VT 6607005 Version M Vxxx Version S Vxxx Version C Vxxx S N Machine S6xxxxxxxx First Level Menu Second Level...

Страница 20: ...Set date and time of the inverter Countercurrent power switch Set the protection parameters of inverter Error Record Wifi Info Date Time Function Enable Setting 5 3 2 Voltage Range Main Menu Setting...

Страница 21: ...e xxx 20ms VH1 XXXV Time xxx 20ms ENT ENT ENT ENT UP DOWN choose Freq Range UP DOWN choose Setting UP DOWN set protection time UP DOWN set protection time press ENT to confirm UP DOWN set level 2 freq...

Страница 22: ...ns Commissioning Procedures Turn on the AC switch between inverter output and the public grid Turn on the DC switch on the inverter Turn on the PV switch of the system 6 Commissioning 7 Start up Shut...

Страница 23: ...on twice a year Earth connection twice a year Heat sink clean with dry towel once a year Fault messages will be displayed when fault occurs please according to trouble shooting table find related solu...

Страница 24: ...till occurs continuously and frequently please ask help for local distributors Isolation Fault PV Fault The impedance between ground and PV PV is too low beyond the reasonable range Check whether the...

Страница 25: ...or too low beyond the reasonable range The temperature of the cooling device is high or low thet beyond the protection range Improve or change the installation environment to adjust the inverter inst...

Страница 26: ...n and remove it Power off then restart Ref Chapter6 If fault still occurs continuously and frequently please ask help for local distributors Eeprom Fault Eeprom abnormal Type of Fault Name Description...

Страница 27: ...0 3 2 EN61000 3 3 EN61000 3 11 EN61000 3 12 IEC 60068 IEEE1547 EN62109 PV Reverse Polarity Protec on PV Insula on Resistance Detec on AC Short Circuit Protec on AC Over Current Protec on AC Over Volta...

Страница 28: ...e If you have any another query please contact our dealer or local vendor from whom you have purchased the product They are trained and ready to serve you at the best INTRODUCTION IN CASE OF ANY QUERY...

Страница 29: ...test manual from www vtacexports com or sales Unless otherwise agreed herein this manual will only be used as guidance Any statement information or suggestion in this manual will not take any form of...

Страница 30: ...ove the Module 1 WIFI MODULE INSTALLATION Implication Lights Status Description All lights are single green lights Communication with router Communication with inverter WIFI Module running status 1 Li...

Страница 31: ...cess to the network 2 Check the router s setting if the connection is limited 3 Contact our customer service 1 Check the connection between WIFI Module and inverter Remove the WIFI Module and install...

Страница 32: ...methods and key press descriptions for Reset button NOTICES FOR RESET BUTTON USER MANUAL FOR SOLARMAN SMART APP Notice Do not remove waterproof plug Key press Status Descrip on Light Status Short pre...

Страница 33: ...packaging or on the logger body 4 Network Configuration After the logger is added please configure the network to ensure normal operation Go to Plant Details Device List find the target SN and click...

Страница 34: ...heck plant data Usually the data will be updated in 10 mins If configuration failure occurs please check the following reason and try it again 1 Make sure WLAN is ON 2 Make sure WiFi is normal 3 Make...

Страница 35: ...r best results make sure each MPPT channel connect with a PV string separately Otherwise the inverter will activate voltage or automatic current protection PV Array 1 PV PV PV PV PV Array 2 PV Inverte...

Страница 36: ...fety when connecting Please make sure the right line of AC grid connected with inverter otherwise inverter could be damaged 1 2 3 3 Quick Installation Instructions SINGLE PHASE INVERTER VT 6607005 Fas...

Отзывы: