6.Control Front Panel Display and Alarms

Outline the menu of High Power Optical Amplifier. For the description of all instructions, please

refer to the panel shown below. Through the buttons on the right side of the LCD screen, you can scroll

through all the menus of the large light.

1. Panel Menus and Operations

1. Boot Sequence

A. Plug in the power cord

B. Turn on the rear panel power switch. The first line of the front panel displays “The

Machine Model” and the second line displays “PTAXXXX-XX-XX”.

C. Press the “up” menu switch button to switch the menu to the laser switch status menu.

That is, the first line of the menu displays “Laser Key State” and the second line

displays the position of “OFF”. Press the “Enter” button and then press the “ESC”

button. At this time, the second line on the front panel displays “Set: OFF”. Then press

the “up” key or the “Down” key to set the switch to the open state, “Set: ON”. Finally,

press the “ESC” key to save and exit the setting. Now, the second line of the front

panel displays “ON” to indicate that the switch is on, and the LED corresponding to

OUT changes from red to green.

2 .Launch the Main Menu

Press the “up” button to scroll up the menu and press the “up” button to display the

following main menus in sequence.

Menu #1 - Descriptor

Equipment Model

Menu #2 - S/N

Product Serial Number

Menu #3 -Version: 2.4.1

Program Version Number

Menu #4 -Rated Output Power

Rated Output Power

Содержание V8616W-16P

Страница 1: ...V8616W 16P High Power Optical Amplifier Installation User Manual Guangzhou V Solution Telecommunication Technology CO LTD V8616W 16P Optical Amplifier ...

Страница 2: ...alarms for all vital characteristics The status and management of the device can be monitored and managed either from the LCD front panel Web or remotely via Ethernet based SNMP The device also support multipul optical output by build in PLC splitter and FWDM 1310nm 1490nm optical multiplexer for Triple play FTTX network applications 2 Features Standard 19 inch 2U Rack YEDFA 32output ports FWDM op...

Страница 3: ...Alarm range Out of 2000mA 4600mA Laser Bias current Pump 16 22dBm 3600mA 200mA 6dBm input Alarm range Out of 2000mA 4600mA Output Power Stability dB 0 1 6dBm Input Noise Figure dB 4 max 5 8 6dBm Input Isolation Input Output dB 30 Return Loss Input Output dB 55 Polarization Dependent Gain dB max 0 5 Polarization Mode Dispersion ps max 0 5 Electrical Specifications Communication Interface RJ45 RS 23...

Страница 4: ...uirements our company s maximum power 1550nmEDFA can work in the temperature range of 0 C 50 C An ambient temperature of 25 C and humidity which is no more than 95 non condensing conditions is recommended If necessary the equipment should maintain proper temperature and humidity within these limits It is recommended that this equipment be operated in a low dust environment 3 The device can be powe...

Страница 5: ...the transmitter s fiber optic connector can be cleaned with a 2 5mm cotton swab or the connector gasket can be removed to directly clean the fiber optic connector inside To remove the connector gasket unscrew the screws on the left and right sides of the gasket Do not screw the bolt with plastic sleeve on the gasket Slowly remove the connector pads from the rear panel of the transmitter and then r...

Страница 6: ...e first line of the menu displays Laser Key State and the second line displays the position of OFF Press the Enter button and then press the ESC button At this time the second line on the front panel displays Set OFF Then press the up key or the Down key to set the switch to the open state Set ON Finally press the ESC key to save and exit the setting Now the second line of the front panel displays...

Страница 7: ...BIAS Pump1 Bias Current Menu 10 COOL CUR Pump1 Cooling Current Menu 11 LD TEMP Pump1 Temperature Menu 12 LD BIAS Pump2 Bias Current Menu 13 Power_1 5V Power Supply 1 Voltage Menu 14 Power_2 5V Power Supply 2 Voltage Menu 15 Temperature in Box Machine Temperature Menu 16 IP ADDR IP address Menu 17 IP GATEWAY IP gateway Menu 18 IP MASK Subnet Mask ...

Страница 8: ...me serious alarms can be eliminated by turning the power off and on again If the relevant parameters return to the normal range the alarm will automatically disappear Most of the warnings are triggered when the error correction capability approaches or exceeds its capability range In most cases users cannot correct these statuses State correction requires specialized equipment and facilities and t...

Страница 9: ...evention Users can prevent many potential problems by paying attention to the following information 1 Place the PUMP laser in an operating range where the ambient temperature is between 0 C and 50 C and other conditions meet the requirements It is recommended to place the Optical Amplifier in a low dust environment 2 Ensure that the rear panel fan and front panel socket holes are clear and the rea...

Страница 10: ... distance may pose an eye hazard Please do not clean the optical signal input interface during lighting Reliable grounding and should be protected by static ESD during operation Connect the optical fibers of all ports before power on The optical connector cannot be plugged or unplugged while the machine is working The machine cannot move or shake while working ...