Description
Unit
Value
Conditions / Notes
Storage Humidity
RH%
≤95
No Condensation
Mechanical Specifications
Dimension
(LxWxH)
mm
483
422
88
Carton:590
590
200
Weight
kg
Net weight 11.7
gross weight :15
Mounting
19” EIA rack, 2U Rack
5.Installation
1.
Unpack
Check the package for obvious damage.
Take out the device from the package.
Check the appearance of the equipment for damage caused by transportation.
If any damage occurs, please informed the shipping company and local agency in written
form.
Keep the package and the insertion for future upgrades or repairs.
Note: When the device returns to the factory, any damage caused by not using the original
packaging will be considered as the responsibility of user.
2.
Assembly and Power Connections
1. Place the device in a 19-inch wide rack or equipment cabinet with 1.75-inch
(approximately 4.5 cm) spacing between the upper and lower equipment.
2. According to the design requirements, our company’s maximum power 1550nmEDFA can
work in the temperature range of 0 °C ~ 50 °C. An ambient temperature of 25 °C and
humidity which is no more than 95% (non-condensing conditions) is recommended. If
necessary, the equipment should maintain proper temperature and humidity within these
limits. It is recommended that this equipment be operated in a low dust environment.
3. The device can be powered by AC or regulated DC. When the AC and DC power supplies
are used, the AC power is the main power source.
The power requirements are as follows:
AC input
94-245 VAC, 50-60 Hz
DC input
36-60 VDC, floating
Power consumption
up to 50 W
4. The DC input power to the device must be the SELV source specified in CAN/CSA C22.2,
No. 950-95.
5. This device should have good grounding and the grounding resistance should be < 4Ω.
Note: Use a large size (#20 AWG, or larger) wire to connect the chassis ground stud to the
grounded equipment rack before connecting the circuit. When using DC input power, the
chassis must be grounded.
3.
Optical Port Connection
1. Clean all optical connectors before connecting the transmitter.
Cleaning steps: