1.5.
Dip-switch settings
1.5.1.
8 dip - black
Some settings have to be selected by the dip-switches on the
video interface.
Dip position down is ON and position up is OFF.
*
The front camera will automatically be switched for 10 seconds after disengaging the
reverse gear (see following information).
After each Dip-switch-change a power-reset of the Video Interface has to be performed!
1.5.1.1.
Activating the front camera input (dip 1)
If set to ON, the interface switches for 10 seconds from the rear-view camera to the front
camera input after having disengaged the reverse gear. In addition, a manual switch-over to
the front camera input is possible via keypad (short press) from any image mode.
Description of the front camera power supply: see chapter “Power supply output”.
1.5.1.2.
Enabling the interface’s video inputs (dip 2-3)
Only the enabled video inputs can be accessed when switching through the interface’s video
sources. It is recommended to enable only the required inputs, disabled inputs
will be skipped when switching through the video-interfaces inputs.
Dip
Function
ON (down)
OFF (up)
1
Front camera
enabled
*
disabled
Power supply
output
(red wire)
+12V (max. 3A) when reverse gear
is engaged incl. 10 seconds delay
and +12V by manual switching to
front camera by keypad
+12V (max. 3A) ACC
2
CVBS AV1-input
enabled
disabled
3
CVBS AV2-input
enabled
disabled
4
No function
Set to OFF
5
Rear-view cam type
after-market
factory or none
6
No function
Set to OFF
7
No function
Set to OFF
8
No function
Set to OFF