RONDA
®
CF-502
RONDA
CF-502
21
V. BRØNDUM A/S
PLEASE NOTE:
If the pre-separator has been used for dust hazardous to health, operators MUST wear personal
protection equipment (PPE) when emptying and handling the machine.
Always empty the machine after use.
Cleaning and maintenance
Always empty the machine after use. If the unit is left with collected material for a longer time – there is a risk for
self-ignition (depending on material)
Clean the outside of the pre-separator with a dry or moist cloth.
Fault finding
If the pre-separator is not delivering full suction:
The suction hose, tube or nozzle may be blocked.
Stop the machine, and remove the blocking.
The collection container or the collection bag may be filled to overflowing.
Stop the machine and empty the container. See the chapter about emptying.
A leak might have occurred when mounting the top.
Start the machine and block the suction hose. Normally you can hear a possible leak.
The collection bag is sucked up inside the container.
1)
The vacuum compensation hose between top and container is not connected.
Connect the 25mm hose to top and container.
2)
A leak in the system.
Check the system for leaks.