Level monitoring system
NT 4600
Technical information / Instruction manual
page
Electrical installation
Cable recommendations for Modbus network
Shielded cable
Functionality up to 50 m
Manufacturer: Lapp, Type UNITRONIC LiYCY 2x 0.34, Art.no: 0034502
Twisted pair cable
Functionality up to 1,000 m
Manufacturer: Lapp, Type UNITRONIC BUS CAN 1x 2x 0.34, Art.no: 2170263
UV-protection hose with threaded hose coupling M20 x 1.5
UV protection for Modbus cable
Manufacturer
: Flexa, Type Rohrflex PA6, Art.no: 0233.202.012 and
Type RQG1-M, Art.no: 5020.055.018
ATEX-protection hose with threaded hose coupling M20 x 1.5
For installation of Modbus cable in ATEX Zone 21
Manufacturer: PMA, Type ESX, Art.no: ESXT-12B.50 and Type END, Art.no: BEND-M202GT
NT 4600
Buzzer and reset button
(Alarm silo full)
Modbus
Fuse: max. 2 A
0.14 .. 2.5 mm
2
(AWG 26 .. 14)
115 V or
230 V
50/ 60 Hz
Wiring of Touch panel
Only relevant if pos.1 A "Touch panel without control cabinet" was ordered
Sub-D female
on Touch panel
Modbus
24 V DC
±20%
350 mA
Fuse: max. 2 A
0.14 .. 2.5 mm
2
(AWG 26 .. 14)
Nivotec
®
1
2
3
4
5
6
7
8
9
10
11
12
NT 4600
gi010417
6