Continuous level measuring system
NB 3000
Technical information / Instruction manual
page G
Programming NB 9000 Remote Box
Programming
• The programming can be done either directly on the Nivobob NB 3000 unit or via the Remote Box NB 9000.
If programming is done on the Nivobob NB 3000 unit, no more programming of the Remote Box NB 9000 is
required.
• All programmed data are stored in the NB 3000 unit and not in the Remote Box NB 9000.
Addressing
• The Remote Box NB 9000 addreses are fixed: Silo1 = Address 1, Silo 2 = Address 2 etc.
The connected NB 3000 units must be set to these addres (see page G31)
Baudrate
• The Remote Box NB 9000 always works with 19200 baud. The NB 3000 units are factory provided with 19200
baud. No setting is necessary.
General
Programming NB 9000 Remote Box
General note
• When operating the display can have a delayed reaction, while the actual data are beeing loaded.
Start after Power On
• The actual Firmware version is displayed
• Press on the Touchscreen to enter into the the Home page
Home page
• Three Silos are indicated per page
The actual level is displayed in m (or feet),
the volume as a bargraph.
• NEXT / PREVIOUS switches to the next or previous silos
• After switching on the power supply, the number of
connected NB 3000 must be set (setting on the last page
next to Silo 10).
• If a "
!"
is stated in the level display, there is no communication between Remote Box NB 9000 and NB 3000.
(Check adress setting on the NB 3000 units, set the number of connected NB 3000 next to Silo 10)
• A flashing level display indicates, that a Maintenance or Failure message is present.
• Press on a Silo to enter in the Overview page per silo
Overview page per silo
• There is one page per silo
• The actual level, volume and volume bargraph is displayed.
A flashing display indicates, that a Maintenance or Failure message is present.
• START will start a measurement of the respective NB 3000. After the sensor weight has reached the material
surface, the display is updated.
• BLOCKED is displayed, if the measurement interruption is active and no measurement can be started. This could
be done manually (see Quickset page below) or by the measurement interruption input (see page G17 and G22) .
• HOME switches back to Home page
• QUICKSET switches to Quickset page
• DIAG switches to Diagnose page
NEXT
PREV.
17.5m
4.5m
22.7m
Silo 1
Silo 2
Silo 3
Silo 1
Level
START
DIAG
QUICKSET
HOME
17.5m
Vol.
65%
BLOCKED