16.  Use the o ring extractor to remove the orifice and the 2 o rings P/N 01.050.360. 
 
17.  Remove the 2 o rings P/N 01.050.147 from the housing with the extractor. 
 
18.  We do not advise removing the inlet tube and the dive / pre dive selector. If the selector is 
hard to move, partially unscrew the retaining screw through the mouthpiece tube and place some 
silicone grease under the selector, screw back the retaining screw and move it up and down 
several times. 
 
19.  Remove the exhaust valve from the diaphragm. 
 
WARNING: It is not advisable to remove the lever linkage and the exhaust retainer from the 
diaphragm. 
 
 

PARTS CLEANING 

 

WARNING: Refer to cleaning procedure 

 
 

ASSEMBLY 

 
1.  After careful inspection of the cleaned parts and the static o rings that do not need to be 
changed, prepare all the parts needed to be changed at every annual service. 
a.  P/N 11.114.012  the poppet assembly or 
°   P/N 11.015.015  the seat 
°   P/N 01.050.323  the poppet o ring 
b.  P/N 01.050.132  the hose o ring 
c.  P/N 11.011.120  the adjustment screw 
 
2.  Place the exhaust valve on the diaphragm. 
 
3.  Assemble the o ring P/N 01.050.132 on the inter stage pressure hose and lightly lubricate. 
 
4.  If the poppet assembly has been taken apart, place the o ring P/N 01.050.323 in the groove. 
Place the seat taking care to place the smooth surface facing the o ring groove. Assemble the o 
ring P/N 01.050.363 on top of the seat, then place the seat retainer and the nut. Hold the middle 
part of the shaft of the poppet with the small pair of pliers and tighten the nut with the 5 mm socket 
wrench. Do not over tighten. Use a minute drop of  thread sealant on the threads of the shaft to 
prevent accidental unscrewing of the nut. 
 
5.  If the orifice has been removed from the  housing, assemble the 2 o rings P/N 01.050.360 in 
the grooves and slightly lubricate. Align the 2 locking tabs with the air inlet holes. Thrust down with 
extreme care the orifice until the 2 locking tabs take their position in the inlet holes. Do not use 
any tool for this operation. Do not allow a nail to come in contact with the sharp edge when 
pushing the orifice. 
 
6.  Align the tab of the aspirator with the cavity in the housing and firmly push. 
 
7.  Place the flow control clip so that the adjustment notches matches the built in nipple. Rotate to 
obtain the biggest surface area of air passage. Rotating this clip to partially obstruct the air 
passage  can drastically reduce the flow characteristics of the regulator.  
 
8.  Place the 2 o rings P/N 01.050.147 in the groove of the housing and lightly lubricate.  

Содержание SCUBAPRO D400 2nd STAGE

Страница 1: ...D400 1 1 MAINTENANCE PROCEDURE FOR D 400 2nd STAGE ...

Страница 2: ...he 3 32 ball Allen key partially unscrew the lever adjustment screw and remove the lever 7 With one finger push on the lever adjustment screw to remove the assembled poppet housing 8 Depending on the version remove the spring adjustment screw with the 3 mm Allen key or the small screw driver Remove the spring pad the spring and the poppet 9 Hold the central part of the shaft of the poppet assembly...

Страница 3: ...ppet assembly has been taken apart place the o ring P N 01 050 323 in the groove Place the seat taking care to place the smooth surface facing the o ring groove Assemble the o ring P N 01 050 363 on top of the seat then place the seat retainer and the nut Hold the middle part of the shaft of the poppet with the small pair of pliers and tighten the nut with the 5 mm socket wrench Do not over tighte...

Страница 4: ... the mouthpiece tube 16 The lever is not symmetrical and will not be in the axis of the poppet housing It is extremely important to position the lever as follows when the complete poppet housing is inserted the lever should not stick out of the diaphragm level If it is so slightly unscrew the lever adjustment screw with the 3 32 Allen key and remove the lever to insert it the opposite way Catch up...

Страница 5: ... poppet assembly and start again the complete adjustment procedure If still unsuccessful with several new poppet assemblies change the orifice see paragraph 5 for assembly and start again the complete adjustment procedure 7 Place the diaphragm as follows Hook the lever into the lever linkage of the diaphragm On the outer periphery of the diaphragm there are 4 injection moulding points 2 of which a...

Отзывы: