SCUBAPRO S600-S550 SECOND STAGES
2003 SCUBAPRO
Important note
: The following information is not designed to be a complete training guide for servicing the listed SCUBAPRO regulators. All SCUBAPRO
technicians are required to attend an annual service training program to insure safe handling and servicing of SCUBAPRO products. All SCUBAPRO technicians
must be employed by an authorized SCUBAPRO facility.
16
Thread the plug inward until there is
enough clearance to install the stop
clip.
Press the stop clip carefully into place.
Back the plug out against the clip
ensuring that it stops.
P/N
43
04
00
00
TOOLS
NEEDED
No tools needed
this step
Inspect the diaphragm for wear, and
replace if necessary.
Install the diaphragm and friction
washer, being certain that the two
pieces lay flat inside the second stage
housing. Note that the friction washer
uses an alignment tab to prevent
movement once installed.
Put the two-piece cover together,
arranging the pieces so that they are
aligned properly. Use the additional
free-moving friction washer between
the two-piece cover and the
diaphragm/stationary friction washer.
Use the universal tool to tighten the
cover, being certain that the
SCUBAPRO “S” is properly positioned.
Install a new housing pin into the side
of the housing.