2. Menus, settings and functions
21
English
measurement of approx 3% (i.e. at a depth
of 30m/100ft, a computer set to salt water
will show 29m/97ft in fresh water whereas
a computer set to fresh water will show
31m/103ft in salt water). Note that this
does not affect the proper functioning of
the computer, since the computer performs
all of the calculations based purely on
pressure measurements.
2.3.7 Desaturation
reset
Galileo allows you to reset the desaturation
in the computer. Any tissue saturation
information from a recent dive will be reset to
zero and the computer treats the next dive
as a non-repetitive dive. This is useful when
the computer is loaned to another diver who
has not dived in the last 48 hours.
!
WARNING
Diving after having reset the desaturation
is extremely dangerous and is very likely to
cause serious injury or death. Do not reset the
desaturation unless you have a valid reason to
do so.
To prevent accidental desaturation reset,
you must enter the safety code once you
decide to proceed with the reset. The
safety code is
313
. Once inside the menu
the word
CODE
will appear. To enter the
code, use the
+
and
-
buttons to defi ne the
fi rst digit (
3
), then
press
>>
to confi rm it.
Now defi ne the next digit (
1
), confi rm by
pressing
>>
, then defi ne the last digit (
3
).
Pressing SAVE
after having defi ned the
last digit will complete the desaturation
process. The display shows the message
DESATURATION RESET SUCCESSFUL
for 2 seconds. Note that the reset of the
desaturation is entered into the logbook for
tracking purposes.
NOTE:
Removing and replacing the battery
will not reset the desaturation. Galileo
stores tissue saturation information
in non-volatile memory. For the time
during which the computer is without
battery, the desaturation calculation
is frozen and resumes from where it
had left off as soon as a new battery is
installed.
2.3.8 All-silent mode (default: OFF)
In this menu you can turn off the sound so
that the computer will not beep under any
circumstance. Setting the
ALL-SILENT
mode to
ON
overrides any setting you
choose for individual warnings (described
in section 2.6) and also mutes all alarms
(described in section 3.2). The wake-up
alarm will also be disabled.
!
WARNING
Muting all alarms can lead you into potentially
dangerous situation and could result in serious
injury or death.
If you choose
ALL-SILENT ON
, you will be
required to enter an additional confi rmation
in the form of a safety code. The safety
code is
313
. This prevents unintentionally