23
English
ALADIN H USER MANUAL
3.4.14 Total ascent time
Total Ascent
Time
As soon as decompression stops are
necessary, the Aladin H shows the total time
of ascent. This includes the ascent time
from the current depth to the surface as
well as all decompression stop obligations.
F
NOTE: The total time of ascent
is calculated on the basis of the
prescribed ascent rate. Total time of
ascent can be subject to change if
the ascent rate is not ideal (100%).
Ascent time greater than 99 minutes
is displayed as “ – – ”.
WARNING
On all dives with the Aladin H, make a safety
stop for at least 3 minutes at a depth of 5m/15ft.
3.4.15 Safety stop timer
Safety Stop Icon
Safety stop time (minutes, seconds)
The safety stop timer displays the time a
diver should spend at the safety stop depth
at the end of the dive. The timer starts
automatically when depth is shallower than
5m/15ft and counts back from 3 minutes
(default) to zero. It can be restarted manually
any number of times. The duration of the
timer can be set between 1 and 5 minutes.
The safety stop timer will be activated under
the following conditions: depth <5m/15ft;
no-stop display of 99 min; the gauge mode
is switched off; stop time is selected (1-5
min) in the scuba mode menu.
You can activate the safety stop timer by
pressing the left button. The timer begins
to count backwards and a bookmark will
be created in the dive profile. If you press
again, the timer will start again from the full
value.
The safety stop timer will switch off
automatically if the depth exceeds
6.5m/21ft or the no-stop phase is shorter
than 99 minutes.
3.5 Functions after the dive
3.5.1
End of a dive
After reaching the surface (<0.8m/3ft)
the Aladin H remains in dive mode for 5
minutes. The delay allows for surfacing for
a short period for orientation.
After 5 minutes, the dive is closed and is
entered into the logbook. The desaturation
time, the no-fly time, the no-dive warning
(if applicable), the current altitude class and
the prohibited altitude class are displayed
for 3 minutes, after which the computer
turns off.
WARNING
For calculations of desaturation and no-fly time
it is assumed that you are breathing air while
on the surface.
Содержание Aladin H