Setting TTL-Converter rotary switch to “0” position can be done only before closing the case, while the housing is open. 
This is a hardwired Manual mode. In this mode the camera does not recognize any device on it’s HotShoe socket, TTL 
protocol in system is totally disabled.  
In this mode TTL-Converter emits single pulse of  fixed (maximum) duration, without Pre-flashes. 
 
This mode is recommended for any creative shooting, for example using long length fiber optical cables (up to 40m 
length is supported), or for usage with TTL incompatible underwater strobes, or for any other difficult situations. 

 

Continuous (Serial) Shooting using underwater strobes 

 

!

 

TTL-Converter supports Continuous shooting in all modes, including TTL and M modes. But the main role in this case plays 
underwater strobes specific (read below). 
 

!

 

Compact  size  underwater  strobes  like  Z240,  Z330,  S2000,  YS-D1,  YS-D2  etc.  have  rather  weak  charger  inside,  which 
cannot charge the strobe quick enough between series of TTL doubled flashes (pre-flash + main flash). Each next shot the 
energy  is  not  enough  to  keep  accurate  pre-flash  duration.  That  is  why,  compact  size  underwater  strobes  are  not 
recommended  for  Continuous  (Serial)  Shooting  in  TTL  mode.  The  1

st

  shot  will  have  normal  lighting,  next  shots  will  have 

different lighting or none at all. The effect depends on specific strobe’s capabilities. 
 

!

 

Large  size  underwater  strobes,  like  YS-250,  DS-161,  DS-160  etc.  have  more  powerful  charger  inside  and  large  main 
capacitor. Those strobes work some better in Continuous (Serial) Shooting TTL mode. The user can make more shots with 
acceptable lighting. However the best lighting accuracy will be on only  the first 1-2 shots in series, the others may have 
different lighting. The effect depends on specific strobe’s capabilities. 
 

!

 

In normal use, all underwater strobes support accurate TTL lighting only in “Single Shot” camera mode. Underwater strobe 
must be fully charged before each flash, to get accurate TTL control. Usually, charge time of modern underwater strobes - 
1

2 seconds. 

 

!

 

For  Continuous  (Serial)  Shooting  with  underwater  strobes,  it  is  strongly  recommended  to  use 

Manual  mode

  and  set 

minimum  strobe  intensities.

 

This  way  it  is  possible  to  get  serial  shots  with  acceptable  lighting  accuracy  due  to  reduced 

recycle times.

 

 

Battery energy saving 

 

!

 

Set acceptable “Power Save Start Time” in camera menu, for TTL-Converter battery saving. Recommended value – 10 sec. 
 

 

 

Storage 

 

!

 

After shooting switch Off the camera. 

!

 

Disconnect TTL-Converter Hot Shoe plug from camera after the diving. This way you protect the TTL-Converter from any 
accidents. Also you save TTL-Converter battery, because current consumption is minimum in this case. 

!

 

For a extended storage periods remove batteries from TTL-Converter. 
 
 

 Warranty 

 

!

 

Product warranted against any manufacturing defects for 2 year from the date of purchase for consumer use. 

!

 

Manufacturer accepts no liability for any damage to and defects in the housing caused by improper use and/or poor 
maintenance. 

!

 

Manufacturer does not hold responsibility for damage of any nature, to any equipment used with the product. 

!

 

Manufacturer accepts no liability for any loss of captured images or the inability to capture images even if it is due to the 
malfunctioning of the product. 

!

 

This warranty only applies to products purchased from authorized dealers and does not extend beyond the original retail 
purchaser. 

!

 

Unauthorized modifications and/or repairs of the product will automatically invalidate this warranty. 

!

 

To return products for service, please contact authorized dealer in your region. 

Содержание 11075

Страница 1: ...tion in standby mode 0 01 mkA Battery capacity 20 C 1 3 years 65 000 flashes Compatible Fiber optic cable type Nauticam 26216 26217 Available Electric Bulkhead type optional accessory Nikonos 5 Ikelite S 6 Dual Electric cables Sea Sea Ikelite support yes Safety Warning for Batteries usage Use batteries only CR2032 type Batteries must be new and undamaged Carefully check batteries before usage To a...

Страница 2: ... deep into the optical bulkheads by any tool The LED must be maximum close to transparent optical element inside the bulkhead to get normal TTL accuracy Bend LED wires as necessary Insert batteries into TTL Converter Before installation check that plus terminal of each battery is in Up position Install upper part of Press Block screw the bolts Optional Accessories UW Technics 91340 Nikonos style B...

Страница 3: ...ommended by your camera User s Manual Shooting in TTL mode Set TTL Converter onboard rotary switch according your strobe type 0 Manual mode TTL protocol is disabled 1 Inon Z240 Z330 2 Sea Sea YS D1 3 Sea Sea YS D2 4 Sea Sea YS 250 5 Ikelite DS 161 DS 160 6 reserved 7 Subtronic Pro 270 8 Subtronic Pro 160 9 Inon S2000 Set main dial switch on the underwater strobe body to TTL mode Please refer to st...

Страница 4: ...but not a fullly electronic shutter Shooting macro for normal TTL accuracy the nearest distance from underwater strobe to a target must be more than 0 35m underwater or more than 0 7m for the land tests to keep the system inside of working TTL range But the camera can be positioned as close to the target as user requires so long as the strobe minimum distance is adjusted TTL Converter is tuned for...

Страница 5: ...3ev 3ev corresponds to flash intensities 1 64 1 1 o Underwater Strobe Manual Mode set by underwater strobe dial switch Set underwater strobe dial switch to M or FULL mode without pre flashes Adjust strobe light intensity by the dial switch on the strobe body Shooting in this mode it is strongly recommended to set TTL Converter also to M mode by camera menu WL command to exclude Pre flashes in syst...

Страница 6: ...s the others may have different lighting The effect depends on specific strobe s capabilities In normal use all underwater strobes support accurate TTL lighting only in Single Shot camera mode Underwater strobe must be fully charged before each flash to get accurate TTL control Usually charge time of modern underwater strobes 1 2 seconds For Continuous Serial Shooting with underwater strobes it is...

Отзывы: