background image

MultiDoc-It Imaging System

 

 

81-0214-01 Rev L 

Introduction 

The MultiDoc-It Imaging System is a high resolution imager capable of capturing and documenting 
fluorescent gel images. The system combines: 
 

1.  MultiDoc-It Darkroom 

2.  DigiCam digital color camera 

3.  Ethidium Bromide (EtBr) Filter 

4.  Doc-It

®

LS Acquisition Software 

5.  UV transilluminator (transilluminator instructions are provided in a separate manual) 

 

NOTE:

 MultiDoc-It TLC Systems (for Thin Layer Chromatography) do not include a transilluminator. 

 

 

Darkroom 

The MultiDoc-It darkroom provides a dark environment for gel UV illumination and protects the DigiCam 
camera. Some MultiDoc-It models include side access doors for moving or cutting gels without opening 
the front door. 
 

UV Filter 

The included emission filter, an orange-colored UV blocking bandpass filter, is used to absorb UV and 
IR radiation from the transilluminator and to enhance the orange/pink bands generated by Ethidium 
Bromide stained gels. The filter can be removed when imaging non-fluorescent media (protein gels, 
colony plates, etc.) in order to produce brighter images. 
 

Camera and Diopter 

The DigiCam digital color camera includes a built-in optical zoom lens. A close-up diopter is connected 
to the lens at the UVP factory. 

Small footprint 

darkroom 

UV-blocking Gel 

Viewer Window 

Wide access door 

DigiCam camera  

with diopter 

Three position filter tray; 

EtBr filter included 

Overhead white light 

Benchtop UV 

Transilluminator 

Side access doors 

(optional) 

Содержание MultiDoc-It

Страница 1: ...er Instructions UVP LLC Ultra Violet Products Ltd 2066 W 11th Street Unit 1 Trinity Hall Farm Estate Upland CA 91786 Nuffield Road Cambridge CB4 1TG UK Phone 800 452 6788 909 946 3197 Phone 44 0 1223 420022 Fax 909 946 3597 Fax 44 0 1223 420561 Web Site www uvp com ...

Страница 2: ...It models include side access doors for moving or cutting gels without opening the front door UV Filter The included emission filter an orange colored UV blocking bandpass filter is used to absorb UV and IR radiation from the transilluminator and to enhance the orange pink bands generated by Ethidium Bromide stained gels The filter can be removed when imaging non fluorescent media protein gels col...

Страница 3: ... Vista or XP SP2 or later Internet Explorer 6 0 or higher To locate the version of Internet Explorer open Internet Explorer and click on Help About Internet Explorer Intel Pentium Processor or equivalent 1 6 GHz or higher 1 GB of RAM or greater 200 MB of available hard disk space for the program more for data CD ROM drive One Universal Serial Bus USB for connecting the camera Color monitor support...

Страница 4: ... back of the darkroom 2 Attach the main power cord to the top rear of the darkroom and the other end of the main power cord into a power outlet a surge suppressor is recommended Figure 1 Filter Installation 1 Unscrew the four plastic head screws Fig 1 that hold the filter tray to the camera mounting plate 2 Remove the filter tray from its position and place the filter s in the square recessed area...

Страница 5: ...osing Restart from the Windows Start menu 5 Double click onto the UVP icon on the desktop 6 Activate the software by choosing On the fly activation if connected to the Internet Complete all the required information on the form and fill in the Serial Number located on the back of the flash drive s tin box Click onto Get Activation No and then click onto Activate when the Activation Number appears i...

Страница 6: ...i overhead white light or optional epi overhead lamp modules Note It is important to minimize the light source exposure to the sample Turn off the light source as soon as the image is captured View a Sample Prior to Capture Samples may be viewed through the Gel Viewer Window when the main darkroom door is closed 1 Open the Gel Viewer Window on the darkroom door 2 After visually verifying that the ...

Страница 7: ...us radio button on the Preview window then use the left and right arrows shown in the red box below to adjust the focus settings Preview Window with Manual Focus 7 When satisfied with the previewed image select Capture at the top of the software Camera Setup Image Acquisition If operating the camera in automatic mode is not sufficient for the application try utilizing the manual mode to gain addit...

Страница 8: ...sed Separately 1 Move the UV Lamp power switch to the ON position 2 Slide the UV Lamps into the lamp brackets inside the darkroom Be sure the lamp power cords are positioned toward the outlets located on back inside of the darkroom 3 Run the lamp power cords over the camera mounting plate and plug into the outlets 4 To use the lamps the darkroom main power switch must to be in the ON position and ...

Страница 9: ... images 89 0038 01 Thermal paper 16 rolls 3200 images 89 0038 04 Thermal Paper 40 rolls 8000 images 89 0038 05 UV to White Light Converter Plate 21x26cm 38 0191 01 UV to White Light Converter Plate 20x40cm 38 0191 02 Visi Blue Converter Plate 21x26cm 38 0200 01 Visi Blue Converter Plate 20x40cm 38 0200 02 Filter 50mm sq SYBR Green and EGFP 38 0219 01 Filter 50mm sq Ethidium Bromide 38 0220 01 Fuse...

Страница 10: ...e for one 1 year from date of purchase Consumable and disposable parts including but not limited to tubes and filters are guaranteed to be free from defects in manufacture and materials for ninety 90 days from date of purchase Transilluminators carry a two 2 year warranty from date of purchase If equipment failure or malfunction occurs during the warranty period UVP shall examine the inoperative e...

Отзывы: