background image

MultiDoc-It Imaging System

 

 

10 

81-0214-01 Rev L 

3.  The transilluminator itself has a power switch; make sure that the transilluminator power 

switch is in the 

“On” position. 

4.  Ensure that the transilluminator power jumper cord is securely connected at both the 

ends. 

Technical

 

Assistance

 

UVP offers expert technical support on all UVP products  If there are any questions about product 
use, operation or repair, contact 

UVP’s offices at the locations below.  

NOTE:

 A Returned Goods Authorization (RGA) number must be obtained from UVP

’s Customer 

Service prior to returning any product. 

If you are in North America, South 
America, East Asia or Australia: 

If you are in Europe, Africa, the Middle East or 
Western Asia: 

Call (800) 452-6788 or (909) 946-3197

, and 

ask for 

Technical Support

 during regular 

business days, between 7:00 am and 5:00 
pm, PST. 

Call +44(0) 1223-420022

, and ask for 

Customer 

Service

 during regular business days between 

9:00 am and 5:30 pm. 

E-mail

 your message to: [email protected] or 

[email protected] 

E-mail

 your message to: [email protected] 

Fax

 Technical Support at (

909) 946-3597

 

Fax 

Customer Service at  

+44(0) 1223-420561

 

Write to:

 UVP, LLC. 2066 W. 11

th

 Street, 

Upland, CA 91786 USA 

Write to

: Ultra-Violet Products Ltd. Unit 1, Trinity 

Hall Farm Estate, Nuffield Road, Cambridge CB4 
1TG UK 

 

Warranty 

UVP's products are guaranteed to be free of defects in materials, workmanship and manufacture for 
one (1) year from date of purchase. Consumable and disposable parts including, but not limited to 
tubes and filters, are guaranteed to be free from defects in manufacture and materials for ninety (90) 
days from date of purchase. Transilluminators carry a two (2) year warranty from date of purchase. If 
equipment failure or malfunction occurs during the warranty period, UVP shall examine the 
inoperative equipment and have the option of repairing or replacing any part(s) which, in the judgment 
of UVP, were originally defective or became so under conditions of normal usage and service. 

No warranty shall apply to this instrument, or part thereof, that has been subject to accident, 
negligence, alteration, abuse or misuse by the end-user. Moreover, UVP makes no warranties 
whatsoever with respect to parts not supplied by UVP or that have been installed, used and/or 
serviced other than in strict compliance with instructions appearing in this manual.  

In no event shall UVP be responsible to the end-user for any incidental or consequential damages, 
whether foreseeable or not, including but not limited to property damage, inability to use equipment, 
lost business, lost profits, or inconvenience arising out of or connected with the use of instruments 
produced by UVP. Nor is UVP liable or responsible for any personal injuries occurring as a result of 
the use, installation and/or servicing of equipment. 

This warranty does not supersede any statutory rights that may be available in certain countries. 

 

 

 

 

 

Doc-It is a registered trademark of UVP, LLC. MultiDoc-It is a trademark of UVP, LLC. 

 

Содержание MultiDoc-It

Страница 1: ...er Instructions UVP LLC Ultra Violet Products Ltd 2066 W 11th Street Unit 1 Trinity Hall Farm Estate Upland CA 91786 Nuffield Road Cambridge CB4 1TG UK Phone 800 452 6788 909 946 3197 Phone 44 0 1223 420022 Fax 909 946 3597 Fax 44 0 1223 420561 Web Site www uvp com ...

Страница 2: ...It models include side access doors for moving or cutting gels without opening the front door UV Filter The included emission filter an orange colored UV blocking bandpass filter is used to absorb UV and IR radiation from the transilluminator and to enhance the orange pink bands generated by Ethidium Bromide stained gels The filter can be removed when imaging non fluorescent media protein gels col...

Страница 3: ... Vista or XP SP2 or later Internet Explorer 6 0 or higher To locate the version of Internet Explorer open Internet Explorer and click on Help About Internet Explorer Intel Pentium Processor or equivalent 1 6 GHz or higher 1 GB of RAM or greater 200 MB of available hard disk space for the program more for data CD ROM drive One Universal Serial Bus USB for connecting the camera Color monitor support...

Страница 4: ... back of the darkroom 2 Attach the main power cord to the top rear of the darkroom and the other end of the main power cord into a power outlet a surge suppressor is recommended Figure 1 Filter Installation 1 Unscrew the four plastic head screws Fig 1 that hold the filter tray to the camera mounting plate 2 Remove the filter tray from its position and place the filter s in the square recessed area...

Страница 5: ...osing Restart from the Windows Start menu 5 Double click onto the UVP icon on the desktop 6 Activate the software by choosing On the fly activation if connected to the Internet Complete all the required information on the form and fill in the Serial Number located on the back of the flash drive s tin box Click onto Get Activation No and then click onto Activate when the Activation Number appears i...

Страница 6: ...i overhead white light or optional epi overhead lamp modules Note It is important to minimize the light source exposure to the sample Turn off the light source as soon as the image is captured View a Sample Prior to Capture Samples may be viewed through the Gel Viewer Window when the main darkroom door is closed 1 Open the Gel Viewer Window on the darkroom door 2 After visually verifying that the ...

Страница 7: ...us radio button on the Preview window then use the left and right arrows shown in the red box below to adjust the focus settings Preview Window with Manual Focus 7 When satisfied with the previewed image select Capture at the top of the software Camera Setup Image Acquisition If operating the camera in automatic mode is not sufficient for the application try utilizing the manual mode to gain addit...

Страница 8: ...sed Separately 1 Move the UV Lamp power switch to the ON position 2 Slide the UV Lamps into the lamp brackets inside the darkroom Be sure the lamp power cords are positioned toward the outlets located on back inside of the darkroom 3 Run the lamp power cords over the camera mounting plate and plug into the outlets 4 To use the lamps the darkroom main power switch must to be in the ON position and ...

Страница 9: ... images 89 0038 01 Thermal paper 16 rolls 3200 images 89 0038 04 Thermal Paper 40 rolls 8000 images 89 0038 05 UV to White Light Converter Plate 21x26cm 38 0191 01 UV to White Light Converter Plate 20x40cm 38 0191 02 Visi Blue Converter Plate 21x26cm 38 0200 01 Visi Blue Converter Plate 20x40cm 38 0200 02 Filter 50mm sq SYBR Green and EGFP 38 0219 01 Filter 50mm sq Ethidium Bromide 38 0220 01 Fuse...

Страница 10: ...e for one 1 year from date of purchase Consumable and disposable parts including but not limited to tubes and filters are guaranteed to be free from defects in manufacture and materials for ninety 90 days from date of purchase Transilluminators carry a two 2 year warranty from date of purchase If equipment failure or malfunction occurs during the warranty period UVP shall examine the inoperative e...

Отзывы: