9
41-1320 REV A
41-1311-01/41-1313
Maintenance
Figure 9
Prefilter
0.3 Micron
High
Efficiency
Filter
6. Insert a new, white 0.3 Micron High Efficiency Filter (marked “First Stage”) into the front of the unit. Ensure
that the WHITE SURFACE FACES FRONT OF UNIT (figure 9 ).
7. Align a new, white Prefilter (marked “Second Stage”) on top of the first filter, or place it inside the inner
frame on the loose grill. Ensure that this filter’s WHITE SURFACE ALSO FACES FORWARD (figure 9).
8. Re-install the front grill, by first sliding the three upper grill end tabs into the upper slots. Ensure that the
Prefilter does not shift or fall out, while pressing down on the two lower corners to snap/lock.
NOTE: Ensure that the metal clips are IN FRONT of the plastic ramps or clips will not snap/lock. Check
that both lower corner clips are locked.
9. Reset the Filter Replacement timer by lightly pressing the RESET button on the front Service Panel,
using a paper clip or stiff wire. When the “Air Filter” LED light turns green, the timer has been reset. This
completes filter replacement.
10. Restore the V-PAC™ SC unit to its normal operating vertical position.
11. Plug the power cord into a wall outlet. Press the “Power” (ON/OFF) switch to operate the unit.