First time UV Lamp installation
1.
Assure power is disconnected from fi xture.
2.
Open the grill door by moving latches
down with fi ngers or a paint safe tool
(Figure 9).
NOTICE: Grill door must be opened prior to
large UV-C chamber door.
3.
Read WARNING label.
4.
Open the large UV-C chamber door
(either a downlight door or a solid metal
door) by moving latches down.
5.
Use clean, cloth gloves carefully remove
the new lamp from box and insert it into
the 2G11 socket and retention clip.
NOTICE: Oil from fi ngers will permanently
etch glass of lamp, weaken structure and
damage to lamp will result. Clean lamp with
rubbing alcohol and clean cloth if necessary.
6.
Close both doors, starting with the large door followed by the grill door and
latch tightly.
7.
Turn on power and confi rm the status light is green (Figure 10) indicating the
UV-C light and fans are on. (See Status Indicator Light table for additional light
descriptions.)
UV Angel Clean Air
TM
downlight can be dimmed wirelessly through the UV Angel
Cloud Portal. To confi gure wall switch dimming instead, follow this procedure.
1.
Assure power is disconnected from fi xture.
2.
Remove and retain 4 screws securing the two electical enclosure covers. Slide
covers inward and pivot to remove.
3.
To disconnect the 2 conductor cable that connects the control module to the
LED driver use a small fl at head screwdriver to depress the terminal block
plungers to remove the wires (Figure 8).
a.
Disconnect control module DIM+ and DIM- wires.
b. Disconnect LED driver Gray and Violet terminal wires.
c.
Remove and discard the 2 conductor cable.
4.
Connect dimmer switch to the LED driver with 18 AWG solid copper wire
rated >300V. Strip wire insulation exposing conductors 3/8” (10mm).
Connect Dim+ wire to violet terminal and Dim- wire to Gray terminal.
5. Reinstall enclosure covers.
FIGURE 10
FIGURE 9
UV Lamp Installation
Optional Downlight 0-10V Dimmer Switch Control
FIGURE 8
Optional Wired Connectivity
Connect ethernet cable to RJ45 port on 102-1255 models for BACnet/IP control
module with no external cloud interface.