Note: This manual does not cover remote controller operation. See the “Remote Controller Instructions” 

packed with the unit for details.

Temperature/Mode

Cooling Operation

Heating Operation

Dehumidifying Operation

Room temperature

62ºF - 90ºF

(17ºC - 32ºC)

32ºF - 86ºF

(0ºC - 30ºC)

< 21,000 BTU models:

50ºF - 90ºF (10ºC - 32ºC)

2100 BTU models

62ºF - 90ºF (17ºC - 32ºC)

Outdoor temperature

5ºF - 122ºF

(-15ºC - 50ºC)

20ºF - 76ºF

(-7ºC - 24ºC)

< 21,000 BTU models:

52ºF - 109ºF (11ºC - 43ºC)

2100 BTU models

64ºF - 109ºF (18ºC - 43ºC)

Note:

1. The unit will perform optimally within the above conditions. If the unit is used outside the above conditions,  
  safety features may begin to operate and the unit may function abnormally. 
2. If the unit operates while the room’s relative humidity exceeds 80%, condensation may form on the surface  
  of the unit. To prevent condensation, set the vertical airflow louver to the maximum opening and set fan    
  mode to high.

1. Lift the front panel until it remains fixed at an angle  
  with a clicking sound.
2. Push the manual control button under the electrical  
  box cover until the auto indicator illuminates. The  
  unit will run in forced auto mode (the default 
  temperature setting is 76°F/24°C). Pressing the 
  manual control button again causes the operation  
  mode to advance through the following sequence:  
  AUTO COOL OFF.
3. Close the panel firmly.
4. To restore remote controller operation, use the 
  remote controller directly.

Manual Operation

Note:

Manual operation should be used only if the remote controller has been disabled or if maintenance is necessary.

Operating Instructions

Low Ambient Operation

This unit features low ambient operation, which means the unit will continue to cool indoors when outside 
temperatures drop as low as 5°F/-15°C. This capability is ideal for locations that require cooling even during 
winter.

AUTO/COOL/OFF

Содержание Split A/C

Страница 1: ...rk must be performed by a licensed professional This appliance should not be used by individuals who lack the experience knowledge or ability to safely operate this appliance unless they receive super...

Страница 2: ...breaker Do not place a heater or other appliances near the power cable Do not disassemble or modify unit If flammable gas leaks turn off the gas and open a window to ventilate the room before turning...

Страница 3: ...s per second when safety protection features are operating 1 AUTO indicator This indicator illuminates when the air conditioner is in auto operation 2 DEFROST indicator This indicator illuminates when...

Страница 4: ...condensation set the vertical airflow louver to the maximum opening and set fan mode to high 1 Lift the front panel until it remains fixed at an angle with a clicking sound 2 Push the manual control...

Страница 5: ...tion CAUTION Auto Operation When the air conditioner is in auto mode it will automatically select between cooling heating and fan only operation to meet the set operating temperature Select desired se...

Страница 6: ...duster to clean the unit Do not use benzene thinner polishing powder or similar solvents for cleaning These may cause the plastic surface to crack or deform Never use water hotter than 104 F 40 C to c...

Страница 7: ...unit blows out dust It is normal for the air conditioner to blow out dust when it has not been used for a long time or during first use of the unit 5 The indoor unit produces an unusual smell The ind...

Страница 8: ...ut Wait for power to be restored Unit has become unplugged Plug unit securely into wall outlet Fuse has blown Replace the fuse Battery in remote controller has been exhausted Replace the battery The t...