INSTALLATION INSTRUCTIONS
HELPFUL TIPS
• This unit is weather-resistant and rated for outdoor use.
• This timer operates using a light-sensitive photocell that senses
when the environment is getting dark (dusk) or light (dawn). The
photocell is located to the upper right on the face of the unit.
• Once programming activates at dusk in the 2hr, 4hr, 6hr or 8hr
mode, the program cycle will complete before the timer resets.
Headlights, porch lights, street lamps and other external lighting
sources will not interfere with the active timer program.
• When set to ON, the unit will provide continual power to
attached devices until the timer is switched to OFF, or to any of
the other operating modes.
• The POWER indicator will glow red when the timer
programming is activated and power is being provided to
attached devices.
OUTDOOR TIMER
ITEM #0154182
MODEL #UTTNOCD2
1. Install unit to a flat surface.
a. Using a screw or hook (not included),
secure the MOUNTING TAB at the top
of the timer to a wall or post.
b. For a more secure mounting, use the
two MOUNTING HOLES on the back
of the timer.
• Create a mounting template by
placing a sheet of paper over the
back of the timer and punching holes
through the paper where the mounting
holes are located on the timer.
• Temporarily secure the mounting
template to the flat surface where
the timer is to be mounted.
• Drill two 3/32 inch pilot holes where
indicated on the mounting template.
• Insert two #6 sheet metal screws
(not included), leaving screw heads
protruding 1/8 inch from the surface.
• Place the timer over the screw heads
and push down to lock into place.
2. Plug unit into an electrical outlet.
Use an outdoor-rated three-pronged
grounded electrical outlet. Do not use
extension cords to connect the timer to
the power source.
3. Set the desired OPERATING MODE.
Rotate the black turn-dial either clockwise
or counter-clockwise to align the mode
with the arrow.
4. Attach up to two devices to unit.
Plug the devices into the outlets on the
bottom of the timer.
WARNING
Risk of Electric Shock
Keep children away. Unplug timer before cleaning. Fully
insert plug. Do not use in wet locations.
Risk of Fire
Do not use to control appliances that contain heating
elements (cooking appliances, heaters, irons, etc.). Do not
exceed electrical ratings.
IN CASE OF POWER FAILURE
The timer will stop operating if the power goes out. Once
power is restored, the timer will restart programming based
on the current mode selected.
3
4
OFF - Power is off to attached devices
ON - Power is on to attached devices
2 Hrs - Power will turn on at dusk and
remain on for 2 hours
4 Hrs - Power will turn on at dusk and
remain on for 4 hours
6 Hrs - Power will turn on at dusk and
remain on for 6 hours
8 Hrs - Power will turn on at dusk and
remain on for 8 hours
Dusk-Dawn - Power will turn on at
dusk and remain on until dawn
SAFETY INFORMATION
This timer is a “GROUNDED” device. The male plug
contains a ground pin and is only intended for use
with a three-pronged grounded outlet.
Do not attach a device that exceeds the unit ratings:
125 V AC / 60 Hz
15 A / 1,875 W Resistive
(General Purpose)
8 A / 1,000 W Tungsten
(Incandescent)
1/3 HP
(Horsepower Motor)
LIMITED 1-YEAR WARRANTY
Prime warrants this product to be free from manufacturing
defects for a period of one year from the original date of purchase
(“warranty period”). This warranty is limited to the repair or
replacement of this product only and Prime is not liable for any
consequential or incidental damage to other products that may
be used with this unit. This warranty is effective only if such unit
is returned to Prime not later than thirty (30) days after the
expiration of the warranty period. Warranty is void if damage is
due to neglect, misuse, alteration, modification, improper
installation, or repair by anyone other than Prime. This warranty
is in lieu of all other warranties expressed or implied. Some
states do not allow limitations on how long an implied warranty
lasts or permit the exclusion or limitation of incidental or
consequential damages, so the above limitations may not apply
to you. This warranty gives you specific rights, and you may also
have other rights which vary from state to state. If unit should
prove defective within the warranty period, return within the time
period set forth above prepaid with dated proof of purchase to:
Prime Wire & Cable, Inc.
ATTN: Timer Warranty
280 Machlin Court
City of Industry, CA 91789
Printed in China
AD
AVERTISSEMENT
Risque de choc électrique
Gardez les enfants à l’écart. Débranchez la minuterie avant de
procéder au nettoyage. Insérez complètement la fiche.
N’utilisez pas l’article dans des endroits humides.
Risque d’incendie
N’utilisez pas cet article pour commander des appareils qui
contiennent des éléments chauffants (appareils de cuisson,
radiateurs, fers, etc.). Ne dépassez pas les capacités électriques.
Call customer service at 1-866-994-4148,
8 a.m. - 6 p.m., EST, Monday - Thursday,
8 a.m. - 5 p.m., EST, Friday.
AB141042
Lights do not
turn on at
dusk.
Lights do not
turn on even
when timer is
in ON
position.
Lights are
flashing
(turning ON
and OFF).
There is too much
ambient light for
the photocell light
sensor to detect
darkness.
Connected lights
are not in ON
position, are not
functioning, or
timer is not
receiving power.
The timer is in
Dusk-to-Dawn
mode and the light
from the connected
lights or other light
source is affecting
the photocell light
sensor.
Move the connected lights
away from the timer or
reposition the timer so it
does not face any other
outside light.
Be sure connected lights
are functional by plugging
them directly into the
outlet. Connected lights
should be in ON position if
they have their own
switch. Make sure the
timer is receiving power -
the red POWER ON light
should come on when
plugged into an outlet and
placed in the ON position.
Move the connected lights
away from the timer or
reposition the timer so it
does not face any other
outside light.
TROUBLESHOOTING
PROBLEM POSSIBLE
CAUSE
CORRECTIVE
ACTION
Power
1a
1b
2
FCC REGULATORY STATEMENT
This device complies with part 15 of the FCC rules. Operation
is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received,
including interference that may cause undesired operation.
Notes: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no
guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following
measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and
receiver.
3. Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician
for help.
IC REGULATORY STATEMENT
Under Industry Canada regulations, this radio transmitter may
only operate using an antenna of a type and maximum (or
lesser) gain approved for the transmitter by Industry Canada.
To reduce potential radio interference to other users, the
antenna type and its gain should be so chosen that the
equivalent isotropically radiated power (e.i.r.p.) is not more
than that necessary for successful communication.
This device complies with Industry Canada licence-exempt
RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including
interference that may cause undesired operation of the
device.