3
598-1292-03
Shell Slot
White to
White
Black to
Black
Junction box ground wire to
green ground screw on fixture.
Gasket
Mounting
Strap
Mounting
Bolt
Rubber
Plug
Mount the Light Control
❒
Align the light control cover plate and cover plate
gasket. Secure with the mounting bolt.
❒
Align the three slots in the decorative shell with the
bulb holder pins. Push the shell in and then twist
clockwise to lock. Repeat for other shell.
❒
Push the rubber plug firmly into place.
WIRING
❒
Remove the existing light fixture.
❒
Install the mounting strap as shown using two screws
that fit your junction box.
❒
The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.
❒
Route the light control’s wires through the large
gasket holes.
❒
Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
Lock Nut
To avoid water damage and electrical shock,
keep bulb holders 30° below horizontal.
❒
Adjust the bulb holders by loosening the lock nuts
but do not rotate the bulb holders more than 180°
from the factory setting. When screwing in the
floodlamps, do not overtighten.
Keep bulbs at least
1" (25 mm) from the
sensor. Do not allow
the bulbs to block
the lens.
Lens
❒
If a wet location junction box was not used, caulk
the wall plate mounting surface with silicone
weather sealant.