SAFETY INFORMATION

•  Prior to service or cleaning this unit, shut off power supply at the panel and lock to  

prevent the power from being turned on. If the panel cannot be locked, clearly mark  

the panel with a warning tag to prevent the power from being turned on.

•  Do not install in a ceiling with insulation greater than R40. (This is required for installations in 

Canada only.)

•  Duct work should be installed in a straight line with minimal bends.

•  Duct work size must be a minimum of the discharge and should not be reduced.  

Reducing the duct size can increase fan noise.

•  This ventilating bath fan is intended for residential use only in 1-2 family dwellings.

•  Never place a switch where it can be reached from a tub or shower.

•  Make sure that the electric service supply voltage is AC 120 V, 60 Hz.

•  Always disconnect the power source before working on or near the unit.

•  This unit is designed and tested to be a supplemental heater for use with a timer or a switch.  

It is not intended to be used as the primary source of heat and controlled by a thermostat.

•  To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray,  

construction dust, etc., off power unit.

•  Provide a separate 20 AMP circuit.

•  This product is designed for ceiling installation only. Do not mount this product in a wall.

•  Install in ceiling only, at least 6 in. from any wall.

•  For greatest efficiency, install heater so heat is directed toward tub or shower area.  

Avoid directing toward walls or windows.

•  Do not install less than 8 ft. (2.4 m) from the floor.

IMPORTANT INSTRUCTIONS

•  Read all instructions before installing or using this heater.

•  Extreme caution is necessary when any heater is used by or near children or invalids and when-

ever the heater is left operating and unattended.

•  Do not operate any heater after it malfunctions. Disconnect power at service panel and have 

heater inspected by reputable electrician before reusing.

•  Do not use outdoors.

•  To disconnect heater, turn controls to OFF and turn off power to heater circuit at main disconnect 

panel.

•  Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may 

cause an electric shock or fire, or damage the heater.

•  To prevent a possible fire, do not block air intakes or exhaust in any manner.

•  A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, 

or flammable vapors or liquids are used or stored.

•  Use this heater only as described in this manual. Any other use not recommended by the  

manufacturer may cause fire, electric shock or injury to persons.

•  SAVE THESE INSTRUCTIONS.

SAFETY INFORMATION

Please read and understand this entire manual before attempting to assemble, operate or install 

the product.

•  Follow all local safety and electrical codes as well as NEC (National Electrical Code) and OSHA 

(Occupational Safety and Health Act).

•  This unit must be properly grounded.

•  Always disconnect the power supply prior to servicing the fan, motor or junction box.

•  Do not bend or kink the power wires. Protect from sharp edges, oil, grease, hot surfaces,  

chemicals or other objects.

•  Do not install where the room air temperature will exceed 40ºC (104ºF).

•  Do not install over a tub or mount in a shower stall enclosure.

•  Do not use to exhaust hazardous or explosive vapors.

•  Do not install in a cooking area.

•  Do not install this fan vertically in a wall.

•  Use this unit in the manner intended by the manufacturer. If you have any questions, please call 

the manufacturer (customer service number located on last page).

•  Installation work must be carried out by a qualified person(s) in accordance with all local and 

safety codes including the rules for fire-rated construction. For use in non-fire rated  

installations only.

•  Sufficient air supply is required for proper combustion and the exhaustion of gases through the 

chimney (flue) of fuel burning equipment to prevent back-drafting. See the standards of NFPA 

(National Fire Protection Association) and ASHRAE (American Society for Heating Refrigeration 

and Air Conditioning Engineers) and the local building code authorities.

•  Exercise care to not damage existing wiring when cutting or drilling into walls or ceilings.

•  Fans should always be vented to the exterior and in compliance with local codes.

•  Do not use this fan with any solid state control device such as a dimmer switch. Solid-state  

controls may cause harmonic distortion, which can cause a motor humming noise.

Содержание 7123-02-l

Страница 1: ...02 L Français p 12 Español p 23 Serial Number Purchase Date Questions problems missing parts Before returning to your retailer call our customer service department at 1 866 994 4148 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Friday AB13699C ATTACH YOUR RECEIPT HERE ...

Страница 2: ...No 7123 02 L Air direction Exhaust and circulation V 120 Hz 60 Duct diameter in 4 Noise sone 1 5 sones Power consumption W 1 400 Heating element coil wattage 1 300 Air deliver at 0 1 in WG CFM 80 CFM PACKAGE CONTENTS PART DESCRIPTION QUANTITY A Grille 1 B Light lens 1 C Fan body 1 D 12 in Suspension bracket 2 E 14 in Suspension bracket 2 A B D C E TYPE IC INHERENTLY PROTECTED THERMALLY PROTECTED L...

Страница 3: ...ventilation or exhaust opening as this may cause an electric shock or fire or damage the heater To prevent a possible fire do not block air intakes or exhaust in any manner A heater has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable vapors or liquids are used or stored Use this heater only as described in this manual Any other use not recommended b...

Страница 4: ... to ensure that Duct work can be run and the area is sufficient for proper ventilation Wiring can be run to the planned location No wiring or other obstructions can interfere with installation 1 Mounting the fan between the joists a Insert either the 12 in suspension brackets D or 14 in suspension brackets E to the duct side and back of the fan body C depending on the distance between the joists b...

Страница 5: ...lectrical contractor to determine this safely WARNING 1 POWER HOUSE ELECTRICAL BOX HOUSE ELECTRICAL BOX NEUTRAL GROUND CAUTION Do not use long wood screw CC in place of medium machine screw BB CAUTION Install a 60 watt maximum light bulb not included CAUTION OPERATING INSTRUCTIONS CAUTION Failure to secure the reflector screws may result in a rattling or humming noise This unit must be properly in...

Страница 6: ...than the purpose shall void this warranty For replacement parts call our customer service department at 1 866 994 4148 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Friday Make sure power is switched off at service panel before servicing the unit To replace bulb Remove lens by gently depressing sides and pull down Use bulb rated up to 60 watts only Allow bulbs to cool before replacing To clean l...

Страница 7: ...L Numéro de série Date d achat Des questions des problèmes des pièces manquantes Avant de retourner l article au détaillant appelez notre service à la clientèle au 1 866 994 4148 entre 8 h et 18 h HNE du lundi au jeudi ou entre 8 h et 17 h HNE le vendredi JOIGNEZ VOTRE REÇU ICI ...

Страница 8: ...rtie et circulation V 120 Hz 60 Diamètre du conduit cm 10 16 Bruit sone 1 5 sone Consommation d énergie W 1 400 Puissance en watts de l élément chauffant hélicoïdal 1 300 Débit d air à 2 54 mm CE m3 min 2 27 m3 min CONTENU DE L EMBALLAGE PIÈCE DESCRIPTION QUANTITÉ A Grille 1 B Lentille du luminaire 1 C Corps du ventilateur 1 D Support de 30 48 cm 2 E Support de 35 56 cm 2 A B D C E TYPE CI À PROTE...

Страница 9: ...qu il soit dans les ouvertures de ventilation ou de sortie d air du radiateur afin de prévenir les dommages causés au radiateur et les risques de choc électrique ou d incendie Afin de prévenir les risques d incendie ne bloquez jamais les ouvertures de ventilation ou de sortie d air de quelque façon que ce soit Un radiateur renferme des pièces chaudes qui produisent des arcs électriques ou des étin...

Страница 10: ...l endroit où vous désirez installer l appareil pour vous assurer que vous pouvez installer un conduit et que l emplacement est suffisamment grand pour une ventilation adéquate le câblage peut se rendre à l endroit prévu aucun câblage ni obstacle ne gêne l installation 1 Installation du ventilateur entre les solives a En fonction de la distance entre les solives insérez les supports de 30 48 cm D o...

Страница 11: ...E À LA TERRE ATTENTION Ne remplacez pas la vis à métaux moyenne BB par une vis à bois longue CC ATTENTION Vissez une ampoule d un maximum de 60 W non incluse ATTENTION MODE D EMPLOI ATTENTION Le fait de ne pas serrer les vis du réflecteur peut entraîner des cliquetis ou des bourdonnements bruyants Cet appareil doit être correctement installé avant d être utilisé Suivez le mode d emploi et les inst...

Страница 12: ...surez vous que l alimentation électrique est coupée à partir du panneau de distribution avant de procéder à l entretien de l appareil Remplacement de l ampoule Retirez la lentille en pinçant légèrement les côtés puis en la tirant vers le bas Utilisez une ampoule d un maximum de 60 W seulement Laissez les ampoules refroidir avant de les remplacer Nettoyage de la lentille et de la grille Retirez la ...

Страница 13: ... Número de serie Fecha de compra Preguntas problemas piezas faltantes Antes de volver a la tienda llame a nuestro Departamento de Servicio al Cliente al 1 866 994 4148 de lunes a jueves de 8 a m a 6 p m y los viernes de 8 a m a 5 p m hora estándar del Este ADJUNTE SU RECIBO AQUÍ ...

Страница 14: ...rculación V 120 Hz 60 Diámetro del conducto cm 10 16 cm Ruido sonios 1 5 sonios Consumo de energía Vatios 1 400 Vataje de elemento de calefacción rollo 1 300 Suministro de aire a 2 54 mm CA m min 2 27 M3 MIN CONTENIDO DEL PAQUETE PIEZA DESCRIPCIÓN CANTIDAD A Rejilla 1 B Lente de luz 1 C Cuerpo del ventilador 1 D Abrazadera de suspensión de 30 48 cm 2 E Abrazadera de suspensión de 35 56 cm 2 A B D ...

Страница 15: ...o ventilación ya que pueden provocar descargas eléctricas incendios o daños en el radiador Para evitar incendios no bloquee las entradas ni salidas de aire de ninguna manera Un calentador contiene partes calientes y piezas que forman arcos eléctricos o que echan chispas No lo use en áreas donde se use o almacene gasolina pintura o vapores o líquidos inflamables Utilice este calentador solo como se...

Страница 16: ...ea suficiente para proporcionar una ventilación adecuada Se pueda instalar el cableado hacia la ubicación planificada No existan cableados ni otros obstáculos que puedan interferir con la instalación 1 Cómo montar el ventilador entre las viguetas a Inserte las abrazaderas de suspensión de 30 48 cm D o las abrazaderas de suspensión de 35 56 cm E en el costado del conducto y parte posterior del cuer...

Страница 17: ...ENCIA 1 FUERZA NEUTRO TIERRA PRECAUCIÓN No utilice tornillos de madera largos CC en lugar de tornillos para metal medianos BB PRECAUCIÓN Instale una bombilla de 60 vatios como máximo no se incluye PRECAUCIÓN INSTRUCCIONES DE FUNCIONAMIENTO PRECAUCIÓN No asegurar los tornillos del reflector puede provocar repiqueteo o zumbido Esta unidad debe instalarse correctamente antes de usarse Siga las instru...

Страница 18: ... a jueves de 8 a m a 6 p m y los viernes de 8 a m a 5 p m hora estándar del Este Asegúrese de que la energía eléctrica esté desconectada en el panel de servicio antes de realizar mantenimiento a la unidad Para reemplazar la bombilla Retire el lente presionando suavemente los costados y jale hacia abajo Utilice solo una bombilla con clasificación máxima de 60 vatios Permita que las bombillas se enf...

Отзывы: