background image

4

Lowes.com

SAFETY INFORMATION

Please read and understand this entire manual before attempting to assemble, operate or install  
the product.

1.  Always disconnect the power supply prior to servicing the fan, motor or junction box.
2.  Installation work must be carried out by a qualified person(s) in accordance to all local and  

safety codes including the rules for fire-rated construction.

3.  Follow all local building, safety and electrical codes as well as NEC (National Electrical Code) 

and OSHA (Occupational Safety and Health Act).

4.  Electric Service supply must be 120 volts, 60 hertz.
5.  This unit must be properly grounded.
6.  Do not bend or kink the power wires.
7.  Exercise care to not damage existing wiring when cutting or drilling into walls or ceilings.
8.  Sufficient air supply is required for proper combustion and the exhaustion of gases through  

the chimney (flue) of fuel burning equipment to prevent back-drafting. See the standards of  
NFPA (National Fire Protection Association) and ASHRAE (American Society for Heating  
Refrigeration and Air Conditioning Engineers) and the local building code authorities.

9.  Do not use this fan with any solid state control device, such as a remote control, dimmer switch,  

or certain timers. Mechanical timers are not solid state devices.

10.  This ventilation fan is approved for use over a bathtub or shower when installed in a GFCI  

protected circuit. Do not use fans over a bathtub or shower that are not approved for that  
application and marked accordingly.

11.  Do not install in a cooking area.
12.  Do not use to exhaust hazardous or explosive vapors.
13.  Fans should always be vented to the exterior and in compliance with local codes.
14.  Do not install in a ceiling with insulation greater than R42.
15.  Duct work should be installed in a straight line with minimal bends.
16.  Duct work size must be the same size as the discharge and should not be reduced. Reducing  

the duct size may increase fan noise.

17.  Prior to service or cleaning this unit, shut off power supply at the panel and lock to  

prevent the power from being turned on. If the panel cannot be locked, clearly mark  
the panel with a warning tag to prevent the power from being turned on.

18.  Use this unit in the manner intended by the manufacturer. If you have any questions. Please  

call customer service. 

PREPARATION

Before beginning assembly of product, make sure all parts are present. Compare parts with package 
contents list and hardware contents list. If any part is missing or damaged, do not attempt to assemble 
the product.  

Estimated Assembly Time: 60 minutes

Содержание 7113-01-L

Страница 1: ...mer service department at 1 866 994 4148 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Friday ITEM 0553449 VENTILATION FAN WITH LIGHT MODEL 7113 01 L Français p 14 Español p 27 AB13917 ATTACH YOUR RECEIPT HERE Serial Number________________ Purchase Date_______________ TM Lowes com ...

Страница 2: ...umption 32 W 120 V 60 Hz Exhaust fan speed 790 RPM Duct diameter 4 in Weight 12 0 lbs Sound output 1 5 Sones Product Specifications 2 Package Contents 3 Safety Information 4 Preparation 5 New Construction Assembly Instructions 6 Existing Construction Assembly Instructions 10 Care and Maintenance 11 Troubleshooting 12 Warranty 13 ...

Страница 3: ... actual size AA BB Long Wood Screw Short Machine Screw Qty 8 Qty 3 C E D PART DESCRIPTION QUANTITY PART DESCRIPTION QUANTITY A Fan body 1 D Suspension bracket II 1 B Grille 1 E Suspension bracket III 1 C Suspension bracket I 1 F GU24 13 watt bulb 2 A B F ...

Страница 4: ...remote control dimmer switch or certain timers Mechanical timers are not solid state devices 10 This ventilation fan is approved for use over a bathtub or shower when installed in a GFCI protected circuit Do not use fans over a bathtub or shower that are not approved for that application and marked accordingly 11 Do not install in a cooking area 12 Do not use to exhaust hazardous or explosive vapo...

Страница 5: ...ling Opening W Ceiling Opening H 9 4 in 9 4 in 7 4 in WIRING DIAGRAM QUICK CONNECTOR INSTRUCTIONS To be sold only with installation instructions WARNING Wiring must comply with all appliable electrical codes Turn OFF power before removing or installing connectors WARNING COPPER TO COPPER ONLY Do not use Aluminum wire CAUTION Accessory part quick connector should meet installation instructions belo...

Страница 6: ...w for thickness of ceiling board used in your appli caton Do not flush mount to joist Flange should be flush with ceiling board 4 Refer to wiring diagram on page 5 Remove the junction box cover Using quick connectors connect house wires to ventilating fan wires black to black white to white green to green Replace the junction box cover CAUTION If your house wires do not match these colors you must...

Страница 7: ...d See dimensions for ceiling hole on page 5 If joist is present insert long wood screws through flange and through ceiling to secure fan to joist 6 Attach plug connector to receptacle 7 Install two 2 GU24 13 watt bulbs F 8 Pinch mounting springs on grille B and insert into narrow rectangular slots inside the fan housing next to the fan motor Turn on electricity at breaker box after finishing insta...

Страница 8: ... BEFORE INSTALLATION Turn off power source Review all safety precautions 1 Remove existing fan 2 Measure the opening to ensure it is large enough to accommodate the new fan body A 9 4 in x 9 4 in 3 If this fan is not replacing an old fan be sure to cut a 9 4 in x 9 4 in opening for the fan body A 4 Insert the suspension bracket into the fan body If spacing between joists is 21 1 4 in to 23 1 2 in ...

Страница 9: ...r thick ness of ceiling board used in your applicaton Do not flush mount to joist Flange should be flush with ceiling board 8 Refer to wiring diagram on page 5 Remove the junction box cover Using quick connectors connect house wires to ventilating fan wires black to black white to white green to green Replace the junction box cover CAUTION If your house wires do not match these colors you must det...

Страница 10: ...e dimensions for ceiling hole on page 5 If joist is present insert long wood screws through flange and through ceiling to secure fan to joist 10 Attach plug connector to receptacle 11 Install two 2 GU24 13 watt bulbs F 12 Pinch mounting springs on grille B and insert into narrow rectangular slots inside the fan housing next to the fan motor Turn on electricity at breaker box after finishing instal...

Страница 11: ... dirt from the fan housing with a vacuum cleaner 3 WARNING Disconnect power supply before servicing See SAFETY INFORMATION before proceeding Routine maintenance should be done at least once a year CAUTION Never use solvents thinner or harsh chemicals for cleaning the fan Do not allow water to enter the motor Do not immerse resin parts in water over 140º F 1 2 ...

Страница 12: ...oise Fan body not securely attached Be sure the fan is securely attached to your ceiling joists The fan is not clearing the room Insuffient intake airflow within room Be sure a door or window is slightly ajar or opened to allow airflow The fan is not able to draw air out of the room without enough airflow to draw from Insuffient CFM Be sure the CFM rating on the fan matches the requirements for yo...

Страница 13: ...not allow exclusions or limitations on an implied warranty the above exclusions and limitations may not apply This warranty gives you specific legal rights and you may have other rights that vary from state to state This warranty is limited to the replacement of defective parts only Labor charges and or damage incurred during installation repair replacement as well as incidental and consequential ...

Отзывы: