background image

5

Lowes.com

PREPARATION

Before beginning assembly of product, make sure all parts are present. Compare parts with package 
contents list and hardware contents list. If any part is missing or damaged, do not attempt to assemble 
the product.  

Estimated Assembly Time: 30 minutes

Tools Required for Assembly (not included): Hammer, Drill Bits, Flathead Screwdriver, Wire Nuts, Nails, 
Duct Tape, Phillips Screwdriver, Utility Knife
Helpful Tools (not included): Electric Drill, Wood Screws

WARNING: Turn off electricity at breaker box before beginning installation.

Carefully remove unit from carton.
Check area above installation location to be sure that wiring can run to the planned location and that 
duct work can be run and the area is sufficient for proper ventilation.
Inspect duct work and wiring before proceeding with installation.
Before installation, provide inspection and future maintenance access at a location that will not interfere 
with installation work.
You may need the help of a second person to install this fan; one person on the attic side and one on 
the room side.
Note: 

I

nstallations may vary depending on how the previous bath fan was installed. Supplies necessary  

for the installation of your bath fan are not all included; however, most are available at your local 
home improvement or hardware store.

DIMENSION REQUIREMENTS

Ceiling  

Opening (L)

Ceiling  

Opening (W)

Ceiling  

Opening (H)

7-3/4 in.

7-13/32 in.

4 in.

WIRING DIAGRAM

QUICK CONNECTOR INSTRUCTIONS

To be sold only with installation instructions.

WARNING:

 

Wiring must comply with all appliable electrical

codes. Turn OFF power before removing or installing connectors.

WARNING:

 

COPPER TO COPPER ONLY. Do not use Aluminum wire.

CAUTION:

 

Accessory part (quick connector) should meet

installation instructions below.

NOTE:

 

The connector is reusable on solid wires of the same wire gage or 

smaller. Do not reuse the connector on stranded wires.

NOTE: 

Important wire information. Maximum temperature rating 105˚C 

(221˚F). 600 volts maximum for building wire and 1000 volts maximum for 
building wire and 1000 volts maximum in signs and lighting fixtures.
The acceptable wire range includes: Solid: 12-18 AWG.

• Strip wires 3/8"-1/2"
• Grip the wire firmly and push
  the stripped end of the wire into
  the open port of the connector.
  Use only one conductor
  per port.
• Verify the stripped end of the
  wires is fully inserted to the
  back of the connector.

Quick

connect

House

wires

Product

wires

FAN HOUSING

Automatic ter minal 

switch

Junction box 

to 

Capacitor for 

long life of 

motor 

MOTOR

to ground

 

switch

White wire

Green wire

Black wire

to 120V/60Hz

WIRING  DIAGRAM

to 

 

switch

to neutral

LIGHT  HOUSING

Candle lamps

to neutral

to ground

Green wire

Содержание 7105-03-L

Страница 1: ...mer service department at 1 866 994 4148 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Friday ITEM 0553447 DECORATIVE VENTILATION FAN MODEL 7105 03 L Français p 13 Español p 25 AB1420 ATTACH YOUR RECEIPT HERE Serial Number________________ Purchase Date_______________ TM Lowes com ...

Страница 2: ...0 V 60 Hz Exhaust fan speed 1 560 RPM Duct diameter 3 in or 4 in Weight 3 65 lbs Sound output 3 5 Sones Product Specifications 2 Package Contents 3 Safety Information 4 Preparation 5 New Construction Assembly Instructions 6 Existing Construction Assembly Instructions 8 Care and Maintenance 10 Troubleshooting 12 Warranty 12 ...

Страница 3: ...CRIPTION QUANTITY PART DESCRIPTION QUANTITY A Fan body 1 D 4 in duct connector 1 B Glass globe 1 E 3 in duct connector 1 C Decorative pan 1 A B HARDWARE CONTENTS shown actual size AA BB Long Wood Screw Short Machine Screw Qty 4 Qty 2 C D E ...

Страница 4: ...ditioning Engineers and the local building code authorities 9 Do not use this fan with any solid state control device such as a remote control dimmer switch or certain timers Mechanical timers are not solid state devices 10 This ventilation fan is approved for use over a bathtub or shower when installed in a GFCI protected circuit Do not use fans over a bathtub or shower that are not approved for ...

Страница 5: ...ver most are available at your local home improvement or hardware store DIMENSION REQUIREMENTS Ceiling Opening L Ceiling Opening W Ceiling Opening H 7 3 4 in 7 13 32 in 4 in WIRING DIAGRAM QUICK CONNECTOR INSTRUCTIONS To be sold only with installation instructions WARNING Wiring must comply with all appliable electrical codes Turn OFF power before removing or installing connectors WARNING COPPER T...

Страница 6: ...fan body to the joist or stud using long wood screws AA where indicated by arrows outside fan body A Hardware Used AA Long wood screws x 4 3 Pull wire through hole 5 1 and into junction box not included Using quick connector secure 120 volt AC house wiring from wall switch to fan as shown in wiring diagram on page 5 Note 12 AWG is the minimum conductor to be used for branch circuit wiring CAUTION ...

Страница 7: ...f fan body A 5 Using two short machine screws BB mount decorative pan C to body Hardware Used BB Short machine screw x 2 6 Install two 40 watt candelabra bulbs not included or two E12 13 watt bulbs not included 7 Mount glass globe B to decorative pan C Place glass globe B against decorative pan C and align indentation in glass globe B with nubs on decorative pan C Rotate glass globe clockwise B un...

Страница 8: ...h to accommodate the new fan body A 7 3 4 in x 7 13 32 in 3 If this fan is not replacing an old fan be sure to cut a 7 3 4 in x 7 13 32 in opening for the fan body A 4 Place the fan body A next to a ceiling joist or wall stud The fan housing should be level and perpendicular to the joist or stud Allow for thickness of ceiling board used in your applica tion DO NOT flush mount to joist Bottom of fa...

Страница 9: ...e minimum conductor to be used for branch circuit wiring CAUTION If your electrical wires do not match the colors listed you must determine what each house wire represents before connecting You may need to consult an electrical contractor to determine safely 7 Install a circular 4 in or 3 in duct not included and secure it with duct tape or clamps neither included Finish ceiling work Ceiling hole ...

Страница 10: ...not immerse resin parts in water over 140º F 1 Rotate glass globe B counter clockwise to remove from decorative pan 40 W 40W 9 9 Install two 40 watt candelabra bulbs not included or two E12 13 watt bulbs not included 10 Mount glass globe B to decorative pan C Place glass globe B against decorative pan C and align indentation in glass globe B with nubs on decorative pan C Rotate glass globe clockwi...

Страница 11: ...d clean the glass globe B in a sink and dry with a cloth 3 Remove dust and dirt from the fan body A with a vacuum cleaner 4 Dampen cloth with dish detergent wipe the fan body A and dry with a cloth Replace the glass globe B 40W 40W 3 2 40W 40W 4 ...

Страница 12: ...pping costs for return product as part of a claim on the warranty must be paid for by the customer Inquiries regarding warranty claims can be directed to 1 866 994 4148 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Friday Printed in China Utilitech UT Design is a registered trademark of LF LLC All rights reserved TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION The fan seems louder than ...

Отзывы: