12
Lowes.com
LIMITED 5-YEAR WARRANTY
If this product fails due to a defect in materials or workmanship at any time during the first FIVE years of
ownership, the manufacturer will replace it free of charge, postage-paid at their option. This warranty does
not cover products that have been abused, altered, damaged, misused, cut or worn. This warranty does
not cover use in commercial applications. Use only manufacturer-supplied genuine warranty repair
replacement parts to repair this fan. Use of non-genuine repair parts will void your warranty. The
manufacturer DISCLAIMS all other implied or express warranties including all warranties of
merchantability and/or fitness for a particular purpose. As some states do not allow exclusions or
limitations on an implied warranty, the above exclusions and limitations may not apply. This warranty
gives you specific legal rights, and you may have other rights that vary from state to state.
This warranty is limited to the replacement of defective parts only. Labor charges and/or damage
incurred during installation, repair, replacement as well as incidental and consequential damages
connected with the above are excluded. Any damage to this product as a result of neglect, misuse,
accident, imporper installation or use other than the purpose SHALL VOID THIS WARRANTY.
Shipping costs for return product as part of a claim on the warranty must be paid for by the customer.
Inquiries regarding warranty claims can be directed to 1-866-994-4148, 8 a.m. - 6 p.m.,
EST, Monday - Thursday, 8 a.m. - 5 p.m., EST, Friday.
Printed in China
Utilitech & UT Design
®
is a registered
trademark of LF, LLC. All rights reserved.
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
The fan seems
louder than it should
CFM too great
Be sure the CFM rating on the fan
matches the size of your room
Damper not working properly or
damaged
Check damper to ensure it is opening
and closing properly. If the damper
has become damaged, please call
Customer Service
Bend in duct too close to fan discharge
Be sure you do not have any sharp
bends in duct closer than 18 in. to the
fan discharge
Fan discharge reduced to fit smaller
duct
Use recommended size ducting to
reduce fan noise
Fan body not securely attached
Be sure the fan is securely attached
to your ceiling joists
The fan is not
clearing the room
Insuffient intake airflow within room
Be sure a door or window is slightly
ajar or opened to allow airflow. The
fan is not able to draw air out of the
room without enough airflow to draw
from
Insuffient CFM
Be sure the CFM rating on the fan
matches the requirements for your
room size
NOTE: Using a tissue is not an
accurate method for determining if
the fan is operating properly. If the
fan clears steam from the room
within approximately 15 minutes of
completeing your shower, then the
fan is operating properly