LongRanger 2050 Operator’s Manual
17
measures the RSSI for that channel and stores its peak valuel. It then displays the data
collected in a graphical or table formats (defaults to “graph”).
The Outdoor Unit contains a test oscillator that may be turned on during this test. Running
the spectrum analysis with the test oscillator on is useful to check the health of the local
radio.
ber-test
This command performs two functions:
1.
The data from the DTE being input at the data port is replaced with a 511 Bit Error Rate
pattern which is transmitted over RF.
2.
The data being received over RF and output to the DTE through the data port is checked
to match the 511 Bit Error Rate pattern. The radio outputs a line, twice a second, with
the results of this check.
In order to test a two way link using this command, you must first set the remote radio in
loopback mode by performing the following steps:
local>
remote
remote>
open
remote>
loopback output-data
remote>
apply
remote>
local
local>
ber-test
At the end of the test, remember to turn off the loopback mode in the remote radio.
6.6
Miscellaneous commands
version
Displays the radio model and software version.
history
Displays the previous commands entered through the console port.
help [command-name]
If no command is specified, displays the complete list of commands. If a command is
specified it displays the valid parameter and corresponding values for that specific command.