LongRanger 2050 Operator’s Manual
13
Sets the radio frequency channel for RF receive. The valid channel numbers range from 5
to 50. Channel 5 corresponds to 2407.78 MHz and channel 50 to 2476.90 MHz. Channels
are spaced 1536 KHz apar (see table below).
pn-code=number
Selects one of the pre-programmed pseudo-noise spreading codes from 1 to 6. The number
of different spreading codes available depends on the spreading code length specified with
the rf-speed command as follows:
PN code length
63
31
15
11
Number of codes
6
6
2
1
antenna=a
or
b
Selects the antenna port in the Outdoor Unit to be used during RF receive.
address=number
Specifies the radio local address for the RF link. Its value can range from 0 to 65536. The
address value can be entered in hexadecimal format by preceding it with 0x. If the address
is specified as all ones (0xFFFF), the radio will accept all RF packets irrespective of the
packet address.
rf-transmit
channel=number
Sets the radio frequency channel for RF receive. The valid channel numbers range from 5
to 50. Channel 5 corresponds to 2407.78 MHz and channel 50 to 2476.90 MHz. Channels
are spaced 1536 KHz apar (see table below).
pn-code=number
Selects one of the pre-programmed pseudo-noise spreading codes from 1 to 6. The number
of different spreading codes available depends on the spreading code length specified with
the rf-speed command as follows:
PN code length
63
31
15
11
Number of codes
6
6
2
1
antenna=a
or
b
Selects the antenna port in the Outdoor Unit to be used during RF transmissions
address=number