![UTICA BOILERS UB95M-200 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/utica-boilers/ub95m-200/ub95m-200_installation-manual_1065213030.webp)
30
XvI - PIPInG And wIRInG APPEndIX
CH C1
L1
T-STAT
L2
CH C2
DHW C2
DHW C1
DHW T2
A2
A1
DHW T1
CH T2
CH T1
OUTDOOR
AIR SENSOR
BOILER CONTROL PANEL
DHW CIRC
L1
120 VAC
L2
CH
CIRC
Basic Wiring Diagram
Single Zone system with domestic hot water priority
Note: The CH & DHW Circulator connections on the boiler
will only support a pump with a 1 amp rating or less.