LIGHTING INSTRUCTIONS

To Turn Off Gas To Appliance

Set the thermostat to lowest setting.

1. 

Turn off all electric power to the appliance if service is 

2. 

to be performed.
Push in gas control knob slightly and turn clockwise  

3. 

  to "OFF." DO NOT FORCE. 

  Replace jacket panel. 

4. 

GENERAL INSTRUCTIONS

Before seasonal start-up, have qualified service agency 

check boiler for soot and scale in the flues, clean burners 

and check gas input rate to maintain high operating 

efficiency.

!

  

CAUTION

Label all wires prior to disconnection when 

servicing controls. Wiring errors can cause 

improper and dangerous operation.

Verify proper operation after service.

Service agency or owner should make certain system is 

filled with water to minimum pressure and open air vents, 

if used, to expel any air that may have accumulated in the 

system. Check the entire piping system and, if any leaks 

appear, have them repaired.

Figure 2 - Circulator

Many circulators like the one pictured in Figure 2 (above) 

require periodic servicing. Motor usually has openings at 
each end to lubricate bearings.

 

Put about one half teaspoon of SAE 20 or 30 non-detergent 

motor oil in each opening twice a year.

!

  

CAUTION

Do Not Over Oil!!

Many circulators have oil opening for shaft bearing. This 

should be oiled at same time for quiet operation. Follow 

manufacturer's instructions for oiling shaft bearing.

Venting system should be inspected at start of each heating 

season. Check vent pipe from boiler to chimney for signs of 

deterioration by rust or sagging joints. Repair if necessary. 

Remove vent pipe at base of chimney or flue and using a 

mirror, check vent for obstruction and make certain vent is 

in good working order.

Figure 3 - Boiler Flue Gas Passageways

BURNERS

ORIFICES

GAS VALVE

HOLD DOWN 

BOLT

FLUE 

COLLECTOR

VENTER 

ASSEMBLY

A1795

Содержание DV

Страница 1: ...the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Do not use this boiler if any part has been under water Immediately call a qualified service technician to inspect the boiler and to replace any part of the control system and any gas control which has ...

Страница 2: ...TICE Indicates information which should be followed to ensure proper installation and operation WARNING Indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided may result in minor or moderate injury Utica Boilers recommends all boiler maintenance be performed by a trained heating technician Before any...

Страница 3: ...a qualified service technician Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under D water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water E F Operating Instructions For Intermittent Pilot System STOP 1 Read the safety in...

Страница 4: ...accumulated in the system Check the entire piping system and if any leaks appear have them repaired Figure 2 Circulator Many circulators like the one pictured in Figure 2 above require periodic servicing Motor usually has openings at each end to lubricate bearings Put about one half teaspoon of SAE 20 or 30 non detergent motor oil in each opening twice a year CAUTION Do Not Over Oil Many circulato...

Страница 5: ...once a 7 month during heating season with few drops of non detergent motor oil SAE 20 or 30 Do not over oil Place sheet of heavy paper or similar material in 8 bottom of combustion chamber and brush down flue passageways Soot and scale will collect on paper and is easily removed with paper Visual check of main burner and pilot flames should be made at start of heating season and again in mid seaso...

Страница 6: ... Orifices GAS VALVE ORIFICES BURNERS Figure 5 Boiler Front with Safety Switch COMBUSTION BURNER REMOVED BURNERS GAS VENT PIPE CHAMBER DOOR VALVE ADAPTER ROLL OUT SAFETY BURNER SWITCH JACKET FRONT PANEL Figure 7 Burners Pilot Flame IGNITION ELECTRODE 3 8 TO 1 2 IN FLAME ...

Страница 7: ...7 NOTES ...

Страница 8: ...TES Date of Installation Boiler Model Installed By Utica Boilers 2210 Dwyer Avenue Utica NY 13504 4729 Phone 315 797 1310 Fax 866 432 7329 e mail info ecrinternational com web site www ecrinternational com ...

Отзывы: